EN 5
energy consumption measuring device BX50 MID / BX50 MID F / BX50 MID C
Technical data
Parameter Value
Model BX50 MID
Weight (packaging
excluded)
approx. 155g
Dimensions
(lengthx widthx height)
approx. 119x 68x 77mm
(with plug)
Display LCD with background illumination
Power supply
230 V AC, single-phase,
50/60 Hz
Power consumption 10 VA
Power loss <2W
Measuring range 0.25 to 5(16)A
Basic current(lb) 5A
Starting current 0.004lb
Accuracy class
1 /
B
Protection class
II/
Indicator resolution 0 to999999.9kWh
0 to999999.9W
Operating conditions -25°C to 55°C
0%RH to 95%RH
(non-condensing)
Storage conditions -40°C to 70°C,
0%RH to 95%RH
(non-condensing)
Measuring category CAT II
Pulse frequency(LED) 1000impulses/kWh
Type of protection IP54
MID certification yes
Information on calibrating the device
The device has a MIDDeclaration of Conformity which replaces
the initial calibration by a calibration authority. The validity of
this declaration expires 8years after placing on the market.
Afterwards the user of the measuring device is obliged to have
the device recalibrated. Further information can be obtained
from your national calibration authority.
Notice
If you are in the position as measuring instrument
operator or if you have been assigned by the
measuring instrument operator to record measured
values, you shall, depending on the intended purpose,
register the usage of new or renewed measuring
devices to your responsible calibration authority within
6hours after initial operation. In this case, please
contact your national verification authority.
To manage the MIDdevices used, you will find a
ready-made form in the appendix or under:
https://hub.trotec.com/?id=43926
Scope of delivery
1 x Energy cost measuring device BX50 MID
1x Quick guide
Transport and storage
Notice
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
When transporting the device, ensure dry conditions and and
protect the device from external influences e.g. by using a
suitable bag.
Storage
When the device is not being used, observe the following
storage conditions:
dry and protected from frost and heat
protected from dust and direct sunlight
the storage temperature complies with the values specified
in the Technical data