B - 21
Operating manual – Infrared camera
Material Temperature
(°C)
Emissivity
approximation
Copper
Copper mirror 100 0,05
Strong copper oxide 25 0,078
Liquid copper 1080 ~ 1280 0,16 ~ 0,13
Brass
Brass mirror 28 0,03
Brass oxide 200 ~ 600 0,61 ~ 0,59
Chrome
Polished chrome 40 ~ 1090 0,08 ~ 0,36
Gold
Gold mirror 230 ~ 630 0,02
11. EMISSIVITY TABLE
Problem Cause Solution
Camera doesn´t work
Power is not turned on.
Turn on the camera.
See Turning the Power On / Off.
Insufficient battery voltage. Fully charge the battery.
Camera will not record.
Internal memory is full
Delete some images to make
some space.
Internal memory not formatted
correctly.
Format the internal memory
in FAT16 format.
Battery pack consumed quickly.
Battery pack capacity reduced
because of disuse for one year or
more after being fully charged.
Replace the battery pack with a
new one.
Battery life exceeded. Replace the battery pack.
Battery pack will not charge.
Poor contact between battery pack
and battery charger.
Clean the battery terminals with
clean cloth. Connect the power
cord to the battery charger and
insert its plug firmly into the
power outlet.
Battery life exceeded. Replace the battery pack.
10. TROUBLE SHOOTING
Poor contact between camera and
battery terminals.
Wipe the terminals with a clean,
dry cloth.
The camera has hung up
Reset the camera
Material Temperature
(°C)
Emissivity
approximation
Aluminium
Polished aluminium 100 0,09
Commercial
aluminum foil
100 0,09
Electrolytic
chromeplate
alumina
25 ~ 600 0,55
Mild alumina 25 ~ 600 0,10 ~ 0,20
Strong alumina 25 ~ 600 0,30 ~ 0,40
Copper