21 EN
Operating manual – local air conditioner PAC 2010 E / PAC 2610 E
Condensate discharge (manual draining)
In cooling and dehumidification mode condensate is formed,
which is mostly discharged via the exhaust air.
The remaining condensate is collected in a container within the
housing. The condensate ought to be drained regularly.
If too much condensate accumulates, the device switches off
and indicates this via the H8 indication on the segment
display(13).
1. Carefully transport or wheel the device to a suitable location
for discharging the condensate (e.g. a drain) or position a
suitable collection container underneath the lower
condensate outlet.
2. Remove the rubber stopper from the condensation drain
hose.
3. Detach the condensation drain hose from the retaining clip
and guide the hose to a drain or collection container. To
ensure that the condensate can run off, the hose must not
be kinked, nor should it have to overcome an uphill incline
towards the drain.
4. Let the condensate run, until the condensation drain hose is
completely drained.
5. Reattach the rubber stopper to the condensation drain hose
and put the hose back into the retaining clip. Ensure the
tight fit of the rubber stopper, for otherwise there might be
uncontrolled water leakage.
ð The H8 error code on the segment display(13) will
disappear as soon as the condensate has been drained.
Refrigerant circuit
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Activities required after maintenance
If you want to continue using the device:
• Leave the device to rest for 12-24hours, so the
refrigerant can accumulate within the compressor. Wait
12-24hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
• Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
• Store the device according to the Storage chapter.