15 EN
Operating manual – local air conditioner PAC 3500 E
Condensate discharge (manual draining)
In cooling and dehumidification mode condensate is formed,
which is mostly discharged via the exhaust air.
The remaining condensate is collected in a container within the
housing. The condensate should be drained manually on a
regular basis.
If too much condensate accumulates, the device switches off
and indicates this via the FL indication on the segment
display(29).
1. Carefully transport or wheel the device to a suitable location
for discharging the condensate (e.g. a drain) or position a
suitable collection container under the condensate
outlet(12).
2. Unscrew the sealing cap from the condensate outlet(12).
3. Remove the rubber plug.
12
4. Slightly tilt or incline the device towards the drain or
collection container.
5. Let the condensate run off completely.
6. Reattach the rubber stopper to the condensate outlet(12).
Check the rubber plug for tight fit.
7. Screw the sealing cap onto the condensate outlet(12).
12
ð The FL indication on the segment display(29) will go out as
soon as the condensate has been drained.
Refrigerant circuit
The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Activities required after maintenance
If you want to continue using the device:
Leave the device to rest for 12-24hours, so the
refrigerant can accumulate within the compressor. Wait
12-24hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.