moisture measuring device T660
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
When transporting the device, ensure dry conditions and and
protect the device from external influences e.g. by using a
suitable bag.
Storage
When the device is not being used, observe the following
storage conditions:
dry and protected from frost and heat
protected from dust and direct sunlight
The storage temperature is the same as the range given in
the Technical data chapter.
Remove the batteries from the device.
Operation
Inserting the batteries
Insert the supplied batteries before first use.
Caution
Make sure that the surface of the device is dry and the
device is switched off.
3
1. Remove the battery compartment cover(3).
2. Insert the batteries with correct polarity.
3. Insert the battery compartment cover(3).
ð The device can now be switched on.
Switch-on
Note:
The cross control is very sensitive. Therefore, avoid dirt on the
control panel, because it could be misinterpreted by the device
as keystroke.
Before use make sure that the touchscreen control panel is dirt-
free.
If required clean the touchscreen control panel according to
chapter Cleaning the device.
1. Hold the device pointing into clear space.
– The device should point away from the body and not at
or near material surfaces. When failing to observe the
above instructions, the following calibration will be corrupt.
2. Press the On/Off button(4) until a beep is emitted.
ð The device performs a short self-test.
ð The device name and firmware version is shown on the
display.
ð The battery charge is indicated on the display.
3. The device carries out an automatic calibration. During
calibration the display indicates the letteringCAL. These
flashing characters are accompanied by brief acoustic
signals. An extended acoustic signal indicates that the
calibration has been completed.
ð The device is ready for operation.

Other manuals for Trotec T660

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trotec T660 and is the answer not in the manual?

Trotec T660 Specifications

General IconGeneral
Penetration DepthUp to 40 mm
Operating Temperature0 °C to +50 °C
Measurement Range0 to 200 digit
Resolution0.1 digit
DisplayLCD