4 EN
moisture measuring device T660
Cross control
No. Designation
7 Up button
8 Right/back button
9 Down button
10 OK button
11 Left/menu button
Display
No. Designation
12 CFG symbol (configuration mode display)
13 Measuring mode
14 Measurement value display top
15 Indication of the unit (moisture in % or CM)
16 Measurement value display bottom
17 Configuration mode
Technical data
Parameter Value
Model T660
Material moisture
Measuring range 1 to 200 digits or
0% to 7.6%
Accuracy 0.1digits or
±0.1%
Resolution 0.1digits
Penetration depth (non-
destructive)
max. 40mm
General technical data
Measuring method Capacitive
Display LCD
Interface USB
Operating conditions 0°C to 50°C with <95 %RH
(non-condensing)
Storage conditions -10°C to 60°C with <95%RH
(non-condensing)
Power supply 4x 1.5 V, AAbatteries
Weight approx. 285 g
Dimensions
(lengthx widthx height)
209mmx 63mmx 35mm
Scope of delivery
• 1x Device T660
• 4x 1.5V batteries, typeAA
• 1 x Factory test certificate
• 1 x Quick guide
• 1 x Display protection film
• 1 x USB cable