EN Operating manual – Material moisture measuring device T660 2
Description of the device
The material moisture measuring device T660 is a dielectric
humidity sensor, which can be used for the quick and
non-destructive localization of humidity or moisture distributions.
The device enables the detection of near-surface moisture in
walls or flooring. The measured values will be displayed in real
time.
A minimum, maximum and average function is available for the
direct analysis of the measured data. Besides, the currently
measured value can be recorded via the hold function.
The device further features an alarm function. Once the preset
limit value is exceeded, the device alerts the user through emit-
ting an acoustic signal!
The device is suited for the preliminary check of the building
materials' readiness for covering for subsequent measurements
according to the calcium carbide method (CM measurement). The
moisture indication allows the localization of the most significant
measuring spots to extract material for the CM measurement.
You can connect the device to a computer by using the USB cable
included in the scope of delivery. Then you can extract and ana-
lyse your measured results with the optional MultiMeasure Studio
software.
Device depiction
Cross control
Display
Information about the device
No. Operating element
1Display
2 Cross control
3 Battery compartment with battery cover
4 On/Off key
5USB interface
6 Measuring head
1
2
6
3
45
No. Operating element
7 Up key
8 Right/back key
9 Down key
10 OK button
11 Left/menu key
No. Display element
12 Configuration mode display
13 Measuring mode
14 Measurement value display top
15 Display of the selected unit
16 Measurement value display bottom
17 Configuration mode options
7
8
11
10
9
TH
HOLD
%WT
g/m
3
g/kg
Pabs[hPa]
SENS MAT TEMP Alarm
Alt.[ft] CAL12
gr/lb dp °C °F % rH
CM m/s ppm °F °C
IR
MAX
DP
MIN AVG
CFG
ACT
14
16
15
12
13
17

Other manuals for Trotec T660

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trotec T660 and is the answer not in the manual?

Trotec T660 Specifications

General IconGeneral
Penetration DepthUp to 40 mm
Operating Temperature0 °C to +50 °C
Measurement Range0 to 200 digit
Resolution0.1 digit
DisplayLCD