EN Operating manual – Material moisture measuring device T660 4
Transport
Use a suitable bag to transport the device safely.
Storage
When the device is not being used, observe the following storage
conditions:
•dry,
protected from dust and direct sunlight,
with a plastic cover to protect it from invasive dust, if neces-
sary.
The storage temperature is the same as the range given in
the chapter Technical data.
When storing the device for a long time, remove the batteries.
Accessories
Optionally, the following accessories are available for transport
and storage:
•TROTEC
®
Holster 3
For further information please contact your TROTEC
®
customer
service.
Inserting the batteries
Insert the supplied batteries before first use.
Caution!
Make certain that the surface of the device is dry and the
device is switched off.
1. Open the cover of the battery compartment (3).
2. Insert the batteries in the compartment as indicated in the
figure.
3. Close the cover of the battery compartment (3).
The device can now be switched on.
Switching on
Note:
The cross control is very sensitive. Therefore, avoid dirt on the
control panel, because it could be misinterpreted by the device as
keystroke.
Before use make sure that the touchscreen control panel is
dirt-free.
If required clean the touchscreen control panel according to
chapter Cleaning the device on page 10.
1. Hold the device pointing into clear space.
The device should point away from the body and not at or
near material surfaces. When failing to observe the above
instructions, the following calibration will be corrupt.
2. Press the On/Off key (4) until a beep is emitted.
The device name and firmware version is shown on the dis-
play.
The battery charge is indicated on the display.
The device carries out an automatic calibration. During
calibration the display indicates the lettering CAL. These
flashing characters are accompanied by brief acoustic sig-
nals.
An extended acoustic signal indicates that the calibration
has been completed.
The device is ready for operation.
Transport and storage
Operation

Other manuals for Trotec T660

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trotec T660 and is the answer not in the manual?

Trotec T660 Specifications

General IconGeneral
Penetration DepthUp to 40 mm
Operating Temperature0 °C to +50 °C
Measurement Range0 to 200 digit
Resolution0.1 digit
DisplayLCD

Related product manuals