EasyManua.ls Logo

Trotec TGP 1025 E - Technical Annex; Technical Data; Safety Signs and Labels on the Device; Cleaning

Trotec TGP 1025 E
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN 13
garden pump TGP 1025 E
5. Use an air gauge to check the precharge pressure at the
pressure tank valve(7). It should be 1.5 to 1.8bar.
6. If necessary, adjust the pressure by pumping in or
releasing air.
7. Screw the protective cap back onto the pressure tank
valve(7).
Safety signs and labels on the device
Check the safety signs and labels attached to the device at
regular intervals. Replace illegible safety signs!
Cleaning
Clean the device with a soft, damp and lint-free cloth.
Protect electrical components from moisture. Do not use
any aggressive cleaning agents such as cleaning sprays,
solvents, alcohol-based or abrasive cleaners to dampen
the cloth.
Rinse the inside of the device with clear, lukewarm water.
Technical annex
Technical data
Parameter Value
Model TGP1025E
Max. feed rate 3300l/h
Max. pump height 30m
Max. suction height 7m
Max. air pressure 3 bar
Automatic switch-on 1.5 bar
Automatic switch-off 3 bar
Pressure tank 19l
Max. water temperature 35°C
Thermal overload protection 150°C
Power supply 230V ~ 50Hz
Power input 1000W
Protection type of the pump IPX4
Protection type of the mains
plug
IP44
Connection type CEE 7/7
Cable length 1.2m
Protection class I
Weight 10.5kg
Dimensions
(lengthx widthx height)
270x 453x 500(mm)
Max. particle size 2mm
Pressure connection 1" internal thread
Suction connection 1" internal thread
Sound values according to EN ISO 3744:1995
Sound pressure level L
pA
72dB(A)
Sound power level L
WA
88dB(A)
Uncertainty K
WA
2dB(A)