12 EN
dehumidifier TTK 100 E
The compressor does not start:
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
Ensure that the relative room humidity complies with the
technical data.
Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or is losing
performance:
Check the air inlets and air filters for dirt. Remove external
dirt.
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The following error messages can be displayed on the segment
display:
Error code Cause Remedy
E1 Temperature
sensor– circuit
interrupted/ short
circuit
Switch off the device and
call the customer service.
E2 Defrost sensor–
circuit interrupted/
short circuit
Switch off the device and
call the customer service.
E3 Humidity sensor–
circuit interrupted/
short circuit
Switch off the device and
call the customer service.
Lo The current humidity
level is lower than
30%RH.
Activate the dehumidifier at
a humidity level which
complies with the technical
data.
Should the alarm persist,
please contact the
customer service.
Hi The current humidity
level is higher than
90%RH.
Activate the dehumidifier at
a humidity level which
complies with the technical
data.
Should the alarm persist,
please contact the
customer service.
E5 Chip communication
failure
Switch off the device and
call the customer service.