10 EN
dehumidifier TTK 96 E / TTK 127 E
Setting the desired relative room humidity
The desired relative room humidity can be preselected at any
time.
1. Press the left or right-hand side of the selection button(22)
to adjust the relative room humidity level.
ð The value for desired room humidity is indicated on the
segment display(20) for approx.5s.
ð Then the currently measured humidity level reappears
on the display.
ð The device switches off automatically upon reaching the
desired value for the relative room humidity.
Setting the fan speed
Using this function you can choose between a low and a high
fan speed. The fan speed can only be adjusted in
dehumidification mode. The default setting for the laundry
drying function is the highest level.
1. Press the TURBO button(24) to switch between the normal
and high fan speed.
ð The TURBO LED(16) is illuminated when the fan runs at
high speed.
Continuous operation
The device dehumidifies the air constantly and regardless of the
current humidity level.
Please proceed as follows to enable continuous operation:
1. Press the CONT. button(25) to switch continuous operation
on or off.
ð With activated continuous operation mode the
CONT. LED(15) is illuminated.
Info
For continuous operation the condensation drain hose
can be connected in order to continuously drain the
accumulating condensate.
Comfort mode
Comfort mode ensures an agreeable humidity level ranging
between 45% and 55%. Depending on the room temperature
the device automatically regulates the convenient humidity level
choosing a value from 45%- 50%- 55%.
In this operating mode it is not possible to regulate the humidity
level manually.
1. Press the COMFORT button(27) to switch comfort mode on
or off.
Setting the timer
For the device to switch on or off automatically after a
predefined number of hours (max. 24hrs) you can programme
the timer.
The timer can be programmed in increments of 0.5hours
(0 to 10h) or in increments of 1hour (10 to 24h).
The timer can be set in all operating modes.
You can activate the function regardless of the device being
switched on or off.
Note
The device must not be left unattended in a freely
accessible room with an activated timer.
Automatic switch-on
ü The device is switched off.
1. Press the TIMER button(23) to programme automatic
switch-on.
ð The On LED(19) is illuminated.
ð The segment display(20) indicates the number of hours
until automatic switch-on. Standard: 0.0
2. Press the Increase value or Decrease value selection
buttons(22) to set the desired number of hours until
automatic switch-on.
ð The number of hours is indicated on the segment
display(20) for approx.5s.
ð The timer setting equals the desired number of hours.
ð After the predefined time, the device switches itself on.
ð The current room humidity level is shown.
Automatic switch-off
ü The device is switched on.
1. Press the TIMERbutton(23) to programme automatic
switch-off.
ð The Off LED(18) is illuminated.
ð The segment display(20) indicates the number of hours
until automatic switch-off. Standard: 0.0
2. Press the Increase value or Decrease value selection
buttons(22) to set the desired number of hours until
automatic switch-off.
ð The number of hours is indicated on the segment
display(20) for approx.5s. Then the current humidity
level of the room will be indicated.
3. The device keeps running until the given switch-off time
has expired or until the device is switched off manually.
ð The timer is now set to the desired number of hours.
ð After the predefined time, the device switches itself off.