1
This quickstart guide provides basic instructions for setting up and using your
SRS2 Stick Reader.
Contents
Unpacking the box .................................. 1
Charging the battery ................................ 2
Getting around ........................................ 2
Recording EID tags .................................. 3
Bluetooth
®
connection............................. 5
Viewing sessions ..................................... 6
Getting information off ............................ 7
Datamars Livestock cloud software .......... 8
Getting help ............................................ 9
Modifying settings ................................. 10
Maintenance and servicing .................... 12
Compliance ........................................... 14
For further information, view the reference
information on the supplied USB stick or visit
tru-test.com
The Datamars Livestock Help Centre provides
searchable articles and videos to help you when
you need it. The Help Centre provides instant
support for our apps, software and products.
Access the help centre via the mobile phone app
or go to support.livestock.datamars.com
1
Unpacking the box
Check that you have all of these items. If anything is missing, contact your supplier.
SRS2 stick reader (the stick reader)
USB stick
contains Data Link PC
software and reference
information.
USB cable
for charging. It also connects
the stick reader to a PC.

Other manuals for Tru-Test SRS2

Questions and Answers

  • A
    April HillSep 9, 2025
    Why doesn’t my Tru-Test SRS2 Scanner beep when scanning a tag?
    • T
      Thomas BoydSep 10, 2025
      If your Tru-Test Scanner doesn’t beep when a tag is scanned or when it is switched on, the Buzzer setting may have been disabled. To enable it, navigate to Home, then Settings, then General, and finally Buzzer. If the buzzer still doesn’t work, check that the LCD is plugged in and the backlight is working, as the buzzer uses the same supply. If both of these are fine, the beeper itself may be faulty, requiring a case replacement. In some cases, the main module might be faulty and need replacement.
  • A
    April NguyenAug 22, 2025
    Why does the battery go flat quickly on my Tru-Test SRS2 Scanner?
    • M
      markbutlerAug 22, 2025
      If your Tru-Test Scanner's battery goes flat quickly, even when fully charged, the battery might be faulty. Try changing to a known good, fully charged battery and verify the stick remains on the Home screen for more than 20 hours. First, turn off the ‘Auto off’ feature by going to Settings, then General, then Auto Off, and choose Disabled. If the problem persists, the main module might be faulty and need replacement. You may need to replace the battery if required.
  • J
    John WoodsAug 25, 2025
    How to fix a Tru-Test SRS2 Scanner that doesn’t power on?
    • S
      susan67Aug 25, 2025
      If your Tru-Test Scanner doesn’t power on when you press the On button, there could be several reasons. The keypad FFC might not be plugged in correctly, so check that it is correctly plugged into connector P105. The keypad itself could be faulty; try using a known good keypad and replace the case if necessary. The battery could also be faulty; test the battery and replace it if needed. In some cases, the stick reader might have been disconnected during a firmware update; use the Data Link firmware recovery feature. As a last resort, the main module might be faulty and require replacement.
  • K
    Kimberly SantiagoAug 26, 2025
    What to do if LCD shows ‘Temperature out of Range’ on Tru-Test SRS2?
    • M
      Michael SmithAug 26, 2025
      If your Tru-Test Scanner is displaying 'Temperature out of Range', it could be due to a few reasons. The temperature might be outside the allowed range of 0 to 45 °C; ensure you charge the device within this range. Alternatively, the battery's internal temperature sensor might be faulty; try charging with a known good battery and replace if required. In some cases, the main module itself might be faulty and require replacement.
  • C
    christopher70Aug 27, 2025
    How to fix a Tru-Test SRS2 when the charging symbol is not cycling?
    • B
      brianmeyerAug 27, 2025
      If the charging symbol on the LCD of your Tru-Test Scanner is not cycling during charging, several factors could be at play. The power adapter might be faulty; try using a known good power adapter and replace if necessary. The USB cable could also be faulty; try a known good USB cable and replace if needed. The battery itself might be faulty; try charging with a known good battery and replace if necessary. In some cases, the internal USB loom might be faulty; try replacing it. As a last resort, the main module could be faulty, requiring replacement.
  • L
    Laura ParsonsAug 29, 2025
    Why is my Tru-Test SRS2 Scanner not vibrating when scanning a tag?
    • T
      Tracy WoodAug 29, 2025
      If your Tru-Test Scanner isn’t vibrating when a tag is scanned, it could be because the Vibrator setting has been disabled. To resolve this, enable the Vibrator setting using the keypad to navigate to Home, then Settings, then General, and finally Vibration. If the setting is enabled and it still doesn't vibrate, the vibrator motor might be faulty, and you should consider replacing it.
  • S
    Stephanie BarkerSep 18, 2025
    What to do if a warning is displayed when scanning with my Tru-Test SRS2 Scanner?
    • Q
      qcookSep 18, 2025
      If, when scanning, your Tru-Test Scanner records a warning, it means the maximum number of records allowed in a session has been reached. To resolve this, start a new session.
  • J
    Johnny BergSep 12, 2025
    How to enable duplicate tag recording on my Tru-Test Scanner?
    • T
      terry54Sep 12, 2025
      If your Tru-Test Scanner won’t record an EID twice in a session, it is because the ‘Allow Duplicates’ feature is disabled by default. To enable it, navigate to Home, then Settings, then Tag Reading, then Allow Duplicates, and press the ‘Scan/Select’ button to change the setting to Yes.
  • S
    Scott CastilloSep 8, 2025
    Why does the battery drop to 80% immediately after charging my Tru-Test Scanner?
    • G
      Gina MillerSep 8, 2025
      If the battery of your Tru-Test Scanner appears to be fully charged but immediately drops to approximately 80% when disconnected from the mains power supply, it indicates a faulty charger circuit. Replace the main module to resolve this issue.
  • H
    Henry BurnsSep 5, 2025
    Why does the LCD flicker when charging my Tru-Test SRS2?
    • E
      Erik ElliottSep 5, 2025
      If the LCD flickers when you attempt to charge the battery of your Tru-Test Scanner, the battery might be faulty. Try charging with a known good battery. Replace the battery if required.

Summary

Unpacking the SRS2 Stick Reader

Charging the SRS2 Stick Reader

Recording EID Tags

Recording EID Tags Standalone

Details the process of scanning EID tags when the reader operates in standalone mode.

Bluetooth Connection

Getting Information Off the Stick Reader

Data Link PC Software

Instructions for transferring data using the PC-based Data Link software.

Data Link App for Mobile Devices

Instructions for transferring data using the mobile Data Link application.

Datamars Livestock Cloud Software

Modifying Settings

Maintenance and Servicing

Tru-Test SRS2 Specifications

General IconGeneral
CategoryScanner
BrandTru-Test
ModelSRS2
ConnectivityBluetooth
UsageLivestock Management
TechnologyRFID
DisplayLCD
Probe Frequency134.2 kHz
WaterproofYes
Power SourceBattery