Hearth
Extensions:
When
a TRUEHEAT®
Fireplace
is
installed
on
a
combustible
floor,
then
a
hearth
extension
constructed
of 4
sheets
of
Va"
thick
Johns-Manville
Cera
Form
106R
Board
or
listed
floor
protector.
If
Cera-Form
Board
is
used,
it
must
be
protected
with
a
minimum
of
26
gage
galvanized
steel
and
may
be
covered
with a
non-combustible
veneer,
such
as
stone,
brick,
tile,
etc.
The
appropriate
size
for
the
hearth
extensions
for
the
TH28, TH36,
and
TH42
models
are
given
in
Table
4
and
are
shown
in Fig. 8.
TABLE
4
MODEL
A B
C
TH28
16
44
8
TH36
20
60
12
TH42
20
66
12
WARNING:
THE
CRACK
BETWEEN
THE
BACK
OF
THE
HEARTH
EXTENSION
AND
THE
FRONT
OF
THE
FIREPLACE
MUST
BE
SEALED
WITH
A
NON-COMBUSTIBLE
MATERIAL
SUCH
AS
GROUT, MORTAR, ETC.
ALSO
PROVIDED WITH
YOUR
FIREPLACE
ARE
TWO
METAL
SAFETY
STRIPS
THAT
MUST
BE
INSTALLED
IN
THE
CRACK
BETWEEN
THE
FIREPLACE
AND
THE
HEARTH
EXTENSION.
THE
SAFETY
STRIP
SHOULD
BE
OVERLAPPED
TO
FORM
ONE
LONG
PIECE
AND
SHOULD
BE
LOCATED
HALF
UNDER
THE FIREPLACE, HALF UNDER THE HEARTH EX
TENSION.
THIS
SAFETY
STRIP
IS
VERY
IMPOR
TANT
BECAUSE
IT
KEEPS
ANY
HOT
EMBERS
THAT
MAY
FALL
INTO
THE
CRACK
FROM
COM
ING
INTO
CONTACT
WITH
THE
COMBUSTIBLE
FLOOR.
SEE
FIG.
9.
GAS
APPLIANCE
ACCESSORIES
If you
intend
to
add
a
gas
appliance
accessory
to your
fireplace
you
must
install
the
gas
line into
the fireplace when you install
the
fireplace. The
gas
line
should
be
constructed
of % in. iron
pipe
and
the
appropriate
iron fittings.
The
gas
line
can
enter
the
fireplace
from
either
side.
With
a
screwdriver
and
hammer,
remove
the
knockout
from
the
outside
wall of
the
fireplace. If
the
fireplace
is
equipped
with
metal
side
panels
in
the
firebox
then
remove
the knockout in
the
side
panel
the
same
way. If
the
fireplace
has
refractory
side
panels,
then
chisel a
hole
as
shown
in FIG. 10. After removing
the
knockout in
the
refractory or metal
side
panel,
remove
one
last
knockout
in
the
fire
chamber
sidewalls.
Next, install
gas
line
through
the
knock
outs
into
the
firechamber
of
the
fireplace. A
minimum
7 in long
nipple
should
be
used
to
reach
the
inside
of
the
fireplace.
Either
cap
off
or
install
gas
log
or
lighter
and
check
for
leaks.
The
gas
line
provision
is
intended
to
be
con
nected
to a
decorative
gas
appliance
only, in
accor
dance
with
the
National
Fuel
Gas
Code,
ANSI Z
223.1
-
1980.
FIQ.8
HEARTH
EXTENSION
SIZES
FOR
TRUEHEAT*
FIREPLACES
SEAL
THIS
GAP
WITH
NON-COMBUSTIBLE
MATERIAL,
SUCH
AS
GROUT
OR
MORTAR
FRONT
BASE
OF
FIREPLACE
vJw;;;;;/;;/Amzb
i
HEARTH
EXTENSION
METAL
SAFETY
STRIP
FIQ.9
INSTALLING THE FIREPLACE
SAFETY
STRIP
FIG.
10
REMOVING KNOCKOUT IN
REFRACTORY
SIDE
PANELS
CHISEL
OR
SCREWDRIVER
\\
I
REFRACTORY
SIDE
PANEL
REFRACTORY
SIDE
PANEL
A.
CHISEL
OFF
NIPPLE
B.
CHISEL
HOLE
TO
DESIRED
SIZE
Page
7
WARNINO:
IF YOU
ATTEMPT
TO
CHISEL
STRAIGHT
THROUQH
THE
REFRACTORY
SIDE
PANEL
BEFORE
REMOVINO
THE
NIPPLE
YOU
MAY
CRACK
AND
BREAK
THE
PANEL.
NEVER
OPERATE
FIREPLACE
IF
REFRACTORY
SIOE
PANELS
ARE
NOT
INSTALLED.