3.5.2 RFID Calibration
The PEX-2000 printer has an RFID antenna coupler design that supports a wide variety of tag types.
Left-hand model
Right hand model
1. Refer to ch.3.3 to load the RFID media.
2. Enter the operation menu list. Go to [Sensor] [Auto Calibration] or [Preprint Calibration] to calibrate the media sensor first.
Note: For RFID with gap type media, it is recommended to use this [Preprint Calibration] item for sensor calibration.
3. Then enter the menu list. Go to [Interface] [RFID] [Tag Calibration] [Do RFID Calibrate] to calibrate the FRID media.
4. Depending on the tag type and tag length, the calibration can take several minutes. At the end of calibration either a Green or
Red window pops up. A green window signifies successful calibration and a red window means calibration has failed.
5. If calibration fails, you will see a red screen. Press the key to clear the failure notice. In some cases it may be due to an
incompatibility between the tag and the reader. After calibration is complete, press the key to continue, the RFID calibration
values will be preserved. For more information, please refer to ch.5.5.7.