6.2 SET GPI
Description
Use this command to receive the GPIO signals from external controlling devices.
Syntax
SET GPIn signal, pulse, function
Parameter
Description
n
n = 1 ~ 4
Four dedicated inputs are available for the desired control functions.
Signal state
HIGH
When a high level signal received, will activate the following printer control functions.
LOW
When a low level signal received, will activate the following printer control functions.
POS
When a positive pulse signal received, will activate the following printer control functions.
NEG
When a negative pulse signal received, will activate the following printer control functions.
Pulse
Filter pulse width. Ignored for level-type signals.
Unit: millisecond. Maximum: 32000.
Function
(control)
PAUSE
Toggle pause status.
PAUSE ON
Enter pause status.
PAUSE OFF
Cancel pause status.
PRINT
Print batch of labels.
PRINT n
n is numerical. Specify how many labels to print. Maximum: 32000.
CUT
Cut immediately.
FEED n
n is numerical and the unit is dot. Specify the feeding length. Maximum: 32000.
BACKFEED n
n is numerical and the unit is dot. Specify the backfeeding length. Maximum: 32000.
FORMFEED
Feeding an empty label.
INPUT n
n is text or command. The n will be triggered to printer.