TR-I serial wireless crane scale user’s manual
- 7 -
sample in the container. the display will show the weight and the units of weight
currently in use.
6.4 Accumulated Total
6.4.1 Note
The scale can be set to accumulate manually by pressing the M+ key. See the
PARAMETERS Section for details of selecting the method using function "F5 P RT".
The accumulation function is only available when weighing.
Please note before every accumulate operate, scale need return to zero, and only
press M+ key when stable, when weight less than 20d, accumulate operate will be
invalid.
6.4.2 Accumulate operate
The weight displayed will be stored in memory when the M+ key is pressed and the
weight is stable.
The display will show "ACC 1" and then the total in memory for 2 seconds before
returning to normal. (after do accumulate operate, M+ indicator will turn on) If the
optional RS-232 interface is installed the weight will be output to a printer or PC.
Remove the weight, allowing the scale to return to zero and put a second weight on.
Press the M+ key, the display will show "ACC 2" and then the new total.
Continue until all weights have been added.
*Note: after you change weighing unit, accumulate value will be clear.
6.4.3 Memory recall
To view the totals in memory press M+ key in zero point (ZERO indicator on).
6.4.4 Memory clear
To clear the memory, just press UNIT key