Press and hold the “SETbuon unl it beeps and then
release it (approx. 5-7 seconds). You are now in the code
programming mode.
A re icon will ash and all 22 res will be displayed.
“FFFF” should be displayed.
Navigate to the re you want to code by quickly pressing
the “SETbuon unl you arrive at the re posion on
the screen.
Enter the rst digit of the four-digit code from the sensor
using the (+) or (-) buons.
Move to the next digit by quickly pushing the “MODE”
buon. Enter the second digit of the code with the (+) or
(-) buons.
Press “MODE” to go to the third digit. Enter it.
Press “MODE” and put in the fourth and nal digit for
that re posion. When done you can:
Quickly press “SETto move on to another re posion
to enter the next four-digit code.
OR
Press and hold the “SET buon to save the code you
entered.
Note: If the right front re is blinking and does not show all “F’s”
you can delete the factory test sensor code as follows:
Press the “SET buon unl it beeps (approx. 4-6
seconds). The display should now show a code other
than “FFFF. This display indicates the re posion is
coded and will show on the Main Screen.
TST-Doc-510 Manual-(A)
Truck System Technologies - 4250 Keith Bridge Road, Suite 200, Cumming, GA 30041
info@tsttruck.com
7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TST TM-510 and is the answer not in the manual?

TST TM-510 Specifications

General IconGeneral
BrandTST
ModelTM-510
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals