MONITOR ALERTS
Out of Parameter Alert
The 510 Cap sensors send the re pressure and temperature
readings to the monitor every two (2) minutes. If a re is outside
the parameters that were set, an immediate audible alarm will
sound and the red LED light will immediately ash. The audible
alarm can be silenced for a short while by pushing any of the
four buons on the front of the monitor. The red warning light
will connue to ash unl the pressure or temperature issue is
resolved and brought back into your preset levels.
Fast Leak Alert
When a fast re leak is detected, the sensor will send that data
immediately to the display. You will see the problem re ash on
the display, the corresponding icon will be seen at the boom
of the screen and the pressure and temperature read-outs will
ash. You will also hear an audible alarm. Again, you can press
any of the four buons on the display face to silence the alarm
for a short while. The screen readout will connue to ash and
alarm unl the problem is corrected.
Sensor Low Baery Alert
The sensor low baery indicator will display when the internal,
non-replaceable baery is at the end of its life. The re aected
will ash along with the pressure and temperature read-out and
the low baery symbol in the lower le corner of the screen will
ash if your display is on. Replace the sensor as soon as possible.
Fast Leak Alert