www.tufner.com
T900 SERIES INDICATOR
USER’S MANUAL
(T900A, T900B Series)

Questions and Answers

  • L
    louiscaldwellAug 2, 2025
    What to do if my Tufner T900 show ERR3?
    • E
      Eric DunlapAug 3, 2025
      If your Tufner Measuring Instruments display 'ERR3', first, check all wire connections. If the issue persists, inspect the load cell and recalibrate the device. If these steps do not resolve the problem, PCB replacement may be necessary.
  • D
    Danielle PatelAug 6, 2025
    What to do if my Tufner T900 show ERR1?
    • K
      kjohnsonAug 7, 2025
      If your Tufner Measuring Instruments display 'ERR1', ensure that you are using the correct weight within the defined range of the instrument.
  • C
    Casey CrawfordAug 10, 2025
    What to do if my Tufner T900 show ERR2?
    • B
      breidAug 11, 2025
      If your Tufner Measuring Instruments display 'ERR2', ensure that the calibration weight is at least 10% of the maximum capacity set in C04. It is recommended to use 60%-80% of the maximum capacity, if possible.
  • J
    Jeffery BryantAug 15, 2025
    Why does my Tufner T900 display UUUUUU?
    • A
      amooreAug 15, 2025
      If your Tufner Measuring Instruments display 'UUUUUU', it could be due to several reasons: the weight might be too high (overload), there could be a wrong connection with the load cell, or the load cell itself may have a quality problem. To resolve this, first, reduce the weight on the instrument. Then, check the load cell connection. Finally, inspect the load cell and check its input/output.
  • M
    Mrs. Danielle HuntAug 20, 2025
    What to do if Tufner T900 show nnnnnnn?
    • P
      powellmariaAug 20, 2025
      If your Tufner Measuring Instruments display 'nnnnnnn', there could be a few reasons: the calibration might not be correct, there may be a wrong connection with the load cell, or the load cell itself might have a quality issue. To address this, first, make sure the scale is level. Next, check the load cell connection. Then, check the load cell's input and output resistance.
  • T
    Tammy RamirezAug 25, 2025
    What to do if Tufner T900 Measuring Instruments show ERR4?
    • J
      John BlackwellAug 25, 2025
      If your Tufner Measuring Instruments display 'ERR4', make sure the platform is stable before you start the calibration process.
  • D
    Danielle RamseyAug 28, 2025
    How to fix ERR5 on Tufner T900?
    • N
      nicole32Aug 28, 2025
      If your Tufner Measuring Instruments display 'ERR5', you will need to change the PCB.

Summary

SAFETY PRECAUTIONS

Anti-Static Prevention Measures

Specific measures to prevent electrostatic discharge and protect equipment.

PREPARATION & SET UP

FEATURES

Technical Parameters

Detailed specifications including accuracy, resolution, and environmental limits.

SPECIFICATIONS

POWER SUPPLY

Battery (Optional)

Guidelines for charging, discharging, and maintaining the rechargeable battery.

OPERATING INSTRUCTIONS

Tare Function

How to use the tare function to exclude container weight and get net weight.

Pre-set Tare Weight

Procedure for setting a specific tare weight value before weighing.

Counting Function

Accumulation

Hold Functions

Print Function

CALIBRATION PROCEDURE

Single Point Calibration

Performing calibration using a single known weight for setup.

Linear Calibration Procedure

INDICATOR PARAMETER SETTINGS

Weighing Unit Configuration

Setting the primary unit of measurement (kg, lb, gram, oz).

Decimal and Graduation Settings

Adjusting display decimal places and readability of graduations.

Capacity and Calibration Settings

Defining maximum capacity and selecting calibration methods.

Communication Settings

Baud Rate Configuration

Setting the communication speed for serial data transmission.

Zeroing and Tracking Parameters

Digital Filter and Stability

Adjusting filters for moving weight and scale stability parameters.

Output Configurations

Print Settings

Customizing print mode, carriage return, and date/time inclusion.

HELPFUL DEFINITIONS

Key Scale Terminology

Definitions for terms like Division, Capacity, Zero Range, and Filters.

CONNECTORS

Load Cell Connections

Details on quick disconnect and hardwire methods for load cell connection.

DB9 Serial Connector

Output Formats Overview

Introduction to the different output formats available for the indicator.

RS232 SERIAL OUTPUT FORMAT

Serial Output Parameters

Explanation of data bits, stop bits, parity, and handshaking settings.

Remote Display Continuous Sending Mode

Data States (A, B, C)

Description of the data structure including states A, B, and C.

Print Mode Configurations

Command Request Mode

Using ASCII commands to control the indicator and retrieve data.

Computer and PC Display Modes

Label Printer Formats

Printing formats for Tufner and Zebra label printers.

4-20 mA ANALOG OUTPUT

Calibration Procedure

Steps to calibrate the 4-20 mA analog output signal.

RELAY OUTPUT

Parameter and Pinout Details

Relay output settings and DB9 pin definitions for connection.

TROUBLESHOOTING

Error Codes and Solutions

Table listing error codes, their reasons, and suggested solutions.

Q&A Section

Common Error Resolutions

Specific solutions for scale not turning on, negative readings, and error codes.

CONTACT US

Tufner T900 Series Specifications

General IconGeneral
BrandTufner
ModelT900 Series
CategoryMeasuring Instruments
LanguageEnglish