ECONOMISER
SERIES
E2T
USER MANUAL
01/03/2016
Manual Release 1.25
Hardware Release 1.3
TURBO
s.r.l.
Electronic Control Systems For Dust Collectors
e-mail: info@turbocontrols.it
web: www.turbocontrols.eu
Tel. ++39 (0)362 574024 Fax ++39 (0)362 574092
Question and Answer IconNeed help?

Do you have a question about the Turbo E2T Series and is the answer not in the manual?

Turbo E2T Series Specifications

General IconGeneral
BrandTurbo
ModelE2T Series
CategoryController
LanguageEnglish

Summary

Technical Specifications

Performance Of The Device

Lists the key features and capabilities of the economiser device.

Electric Specifications

Warning Symbols Used In This Manual

Installation Rules Notes and Warnings

Display / Keypad

List Of Functions

F01: Configuring the operation mode

Sets the operating mode: Manual, Automatic, Automatic with forced cycle, or Proportional.

F08: Cleaning cycle start threshold high dP set point

Defines the dP level that triggers the start of a cleaning cycle.

F09: Cleaning cycle stop threshold low dP set point

Defines the dP level that suspends the cleaning cycle.

F10: Max dP Alarm Threshold

Sets the dP level that triggers a maximum pressure alarm.

List Of Functions Continued

F21: Min dP Alarm Threshold

Sets the minimum dP threshold for the alarm (broken sleeve/cartridge).

Alarms

E09: dP maximum pressure exceeded alarm

Alarm triggered when maximum dP is exceeded for an extended period.

Description Of Operation

Automatic Mode (F01=1)

Explains how the device operates autonomously for pneumatic cleaning based on dP.

Manual Operating Mode (F01=0)

Details how the economiser functions as a programmable cycle sequencer in manual mode.

Automatic Mode With Forced Cycle (F01=2)

Describes forced cleaning cycles initiated independently of dP thresholds.

Proportional Mode (F01=3)

Cleaning Function With Fan Off (PCC)

Precoating Function (F18=1)

dP Zero Calibration (F07)

dP Sensor Self-Calibration

Connection Diagram

Contacts And Relay Terminal Block J2

Terminals Table

Jumper Configuration - Power Input

Jumper Configuration - Output

Installation - Casing Dimensions 4 / 8 Outputs

Installation - Casing Dimensions 12 / 16 Outputs

Default Settings

Problem Solution FAQ

Display Issues

Troubleshooting steps for when the display does not light up.

Output Activation Problems

Resolving issues where outputs are not activated.

Differential Pressure Reading Errors

Diagnosing and correcting incorrect differential pressure readings.

Cleaning Cycle Execution

Troubleshooting why cleaning cycles are not carried out or start incorrectly.

Alarm Activation and Signaling

Addressing issues with alarm messages and signaling devices.

Economiser Reset Issues

Investigating causes for the economiser occasionally resetting.

Zero dP Display Value

Troubleshooting why the 0.0 kPa value does not appear when the fan is off.