Connection layout to the ERCP pilot enclosure boxes
Connect the 3-wire cable coming from the IN connector of the first pilot enclosure box for pneumatic
drive (ERCP) present in the system, to the P11 connector of the Econet control unit, as shown in the
following layout:
Key:
Connection pipe between remote pilot and the valve
Enclosure with built-in pilots for driving valves
Connection cabling between the ERCP pilot enclosure boxes
Connection cabling between the control unit and the pilots
enclosure box
Several pilots enclosure boxes are present in the system; connect them in
sequence in a way that the OUT connector of an ERCP pilots enclosure
box is connected to the IN connector of the next ERCP pilots enclosure
box.
Use a connection cable made with a DIN 43650 connector, to fix onto a
cylindrical base, making sure that the relative IP sealing gaskets are
mounted.
Complete installation by hermetically closing the OUT connector of the
last ERCP pilots enclosure box present in the system.