13
Advanced Set Up
Description
Unit
of
measurement
Factory
settings
Range
2.1
dP Fan On/Off
The threshold value for fan on or off
recognition is set (used for Post-cleaning
function)
KPa/1000
100
0
10000
2.2
Cleaning fan off
The number of complete washes with fan off
is set
2
0
100
2.3
Pulse time (ms)
The duration of opening (shot) of the valve,
with fan off, is set
msec
200
50
5000
2.4
Cycle time (sec)
The time interval between the opening of
one valve and the next, with the fan off, is
set
sec
10
1
7200
2.5
Precoating
Enables the Precoating function.
Disable
Disable
Enable
2.6
dP Precoating
the pressure value to maintain the
Precoating function enabled is set. When the
value is exceeded, the control unit returns
to the original operating mode.
KPa/1000
1500
0
10000
2.7
Cycles Man. Spec.
The number of complete cycles to be carried
out in Special mode is set
2
0
50000
2.8
Pause Man. Spec.
The pause time between the cycles in
Special mode is set
Sec
20
0
43200