TURBO s.r.l. Dust Filter Components
Via Po 33/35 20811 Cesano Maderno (MB) Italy Tel ++39 0362 574024 Fax ++39 0362 574092
Advanced Set Up
dP Fan On/Off
The threshold value for fan on or off
recognition is set (used for Post-cleaning
function)
Cleaning fan off
The number of complete washes with fan off
is set
Pulse time (ms)
The duration of opening (shot) of the valve,
with fan off, is set
Cycle time (sec)
The time interval between the opening of
one valve and the next, with the fan off, is
set
Precoating
Enables the Precoating function.
dP Precoating
the pressure value to maintain the
Precoating function enabled is set. When the
value is exceeded, the control unit returns
to the original operating mode.
Cycles Man. Spec.
The number of complete cycles to be carried
out in Special mode is set
Pause Man. Spec.
The pause time between the cycles in
Special mode is set