EasyManua.ls Logo

Turbo Eco-Net 128 - General Features

Turbo Eco-Net 128
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
U s e r I n s t r u c t i o n s
Eco-Net 128 Control Unit
4
TURBO s.r.l. Dust Filter Components
Via Po 33/35 20811 Cesano Maderno (MB) Italy Tel ++39 0362 574024 Fax ++39 0362 574092
InMn 26 UCESTD
Rev.1.02 it
General features
Power supply voltage
10240Vac 50-60 Hz
Optional: 24Vac/Vdc ± 10 %
Electric consumption (with Ton max=10sec)
25W at max load
(35W per 24Vac/Vdc IN)
Protection fuse
1A (100÷240Vac IN)
3A (24Vac/Vdc IN)
Operating temperature
-10 °C - 55 °C
Storage Temperature
-20 °C - 60 °C
Environmental humidity
0 ÷ 95% Rel. (Non Condensing)
Pressure Transducer
0 ÷ 10Kpa (max 40Kpa) (*)
Maximum pressure applicable
50KPa 0.5 bar
High pressures
damage the device
Pulse Time (valve opening)
50msec ÷ 5sec
Pause time (interval between valves opening)
1sec ÷ 7200sec
Proportional output 4 ÷ 20 mA
1x 20mA current Loop
(self-powered)
Alarm Relays
2 N.C. (voltage-free contact)
24Vac/dc 5Amp (**)
Display
Monochrome graphic LCD
B/N 128 x 64 Pixel.
Casing
ABS base
Polycarbonate Lid
Protection rating from water and dust
IP65 (DIN EN 60529)
Shock resistance
IK08/07 (8 Joule) (En62262)
Flammability
(UL746C 5): UL 746C 5V
Resistance to UV rays
UL508
Seals
EPDM and polyurethane
Colour
RAL 7035
Overall weight
1.1 Kg
Note(*):
Higher pressures may damage the transducer Do not connect clogging measuring tubes to
the compressed air circuit.
Note(**):
For 230Vac 5Amp relay contacts, request the optional Piggy-back 2 RELAYboard