U s e r I n s t r u c t i o n s
Eco-Net 128 Control Unit
16
TURBO s.r.l. Dust Filter Components
Via Po 33/35 20811 Cesano Maderno (MB) Italy Tel ++39 0362 574024 Fax ++39 0362 574092
InMn 26 UCESTD
Rev.1.02 it
Continues....
Description
Parameter
Unit
of
measurement
Factory settings
Range
6.6
Method of activation of Relay 2
The activation mode of Relay 2 during
the associated alarm is set
RL2: Mode:
Time
Pulse
Latch
6.7
Duration of activation of Relay 2
The duration of activation of Relay 2
during the associated alarm is set, if
the previous parameter is configured
"Time"
RL2: Time:
Sec.
00010
0
50000
6.8
Status of Relay 3 contact
The rest status of Relay 3 alarm
contact is set
RL3:No/Nc:
Close
Open
Close
6.9
Method of activation of Relay 3
The activation mode of Relay 3 during
the associated alarm is set
RL3: Mode:
Time
Pulse
Latch
6.10
Duration of activation of Relay 3
The duration of activation of Relay 3
during the associated alarm is set, if
the previous parameter is configured
"Time"
RL3: Time:
Sec.
00010
0
50000
6.11
Enabling alarm buzzer
Buzzer enabling is set
Buzzer
Enabl
Enabl
Disab