Project No. File:
? H@ = 47.365
% Oxygen = 20.61
%O
2
% Carbon = 0 %CO2
Temperature
= 25 °C
Pressure
= 744.22 mmHg
Pressure
= -5.08
mm H2O
root ?P
= 2.336
?P mm H2O
Pressure Velocity Pressure
5.08 1450
5.334
5.334 1500
6.096
5.08 1600
5.334
5.842 1650
5.588
8 1518.75
Ft/sec
Temperature
= 25 °C
Coefficient
= 0.84
= 23
= 21.24 Lpm
Size
8.194 mm
0.322598 in
Size Used
3/8 in
# Travers Points
When numbers are entered into calculator, ideal nozzle
size will be displayed. Enter number here
If ideal nozzle size is not available, locate nearest
number. Enter what nozzle size was used for testing
This number is calculated when device is calibrated
Oxygen inside stack during operation
Carbon Dioxide inside stack during operation
08NK02927
Turbochef
Calculations needed for Nozzle Size
E151487
i5 Oven
Temperature inside stack during operation
Barametric pressure at location of meter
Static Pressure inside of duct
Enter pressure differential at each transvers point in mm
H2O, the take square root of ?P.
Velocity
1500
1600
1450
1400