Do you have a question about the turck TBEN-LG-16DXP and is the answer not in the manual?
Category | Adapter |
---|---|
Input Voltage | 24 V DC |
Output Voltage | 24 V DC |
Input Type | Digital |
Protection Class | IP67 |
Power Supply | 24 V DC |
Number of Inputs | 8 |
Number of Outputs | 8 digital outputs |
Communication Protocol | EtherNet/IP, Modbus TCP, PROFINET |
Operating Temperature | -40°C to +70°C |
Connection Technology | M12 connectors |
Product Description | Compact multiprotocol I/O module for field installation |
Table listing part numbers for different TBEN-LG models with detailed specifications.
Detailed connection diagram for the TBEN-LG-16DIP module, showing ports and pin assignments.
Connection diagram for TBEN-LG-8DIP-8DOP, detailing Ethernet, Input, Output, and Power connections.
Connection diagram for TBEN-LG-16DOP, illustrating its port pinouts for various interfaces.
Connection diagram for TBEN-LG-16DXP, showing its interface pin configurations.
Table detailing the status and description of Ethernet port LEDs and device fault LEDs.
Explanation of the Power LED status for different TBEN-LG device models.
Details on IO LEDs for TBEN-LG-16DIP, covering input and output channel status.
Description of IO LEDs for TBEN-LG-16DOP, indicating input and output states.
Explanation of IO LEDs for TBEN-LG-8DIP-8DOP, for both input and output channels.
Details of IO LEDs for TBEN-LG-16DXP, covering input/output and overload conditions.
Explanation of the IO data format, including abbreviations and bit assignments for TBEN-LG-16DIP.
IO data format structure for TBEN-LG-8DIP-8DOP, detailing input and output data mapping.
IO data format for TBEN-LG-16DOP, showing bit assignments for input and output data.
Configuration data structure for TBEN-LG-16DXP, detailing byte and bit assignments.
Procedure for IP address assignment using BOOTP/DHCP modes with rotary switch settings.
Details on PGM-DHCP mode for IP address assignment, including default setup.
Using the web server to configure IP address in PGM mode, including login procedure.
Procedure for Restore Mode (0) to revert IP address to factory default.
Steps for Factory Reset Mode (900) to restore all device settings to defaults.
Steps for configuring TBEN devices using EDS files with RSLogix5000.
Setting up the EtherNet/IP user interface with RSLinx for ControlLogix platform.
Steps to create or open an RSLogix5000 project for TBEN device configuration.
Procedure to install EDS hardware files using the Rockwell Automation EDS Wizard.
Steps to create a new TBEN module within an RSLogix5000 project.
Configuring connection type and data format for TBEN modules in RSLogix5000.
Selecting the integer IO data format and understanding CIP connection types for TBEN.
Parameters for TBEN digital inputs: Pulse_stretching and Input_Inversion.
Parameters for TBEN digital outputs: Disable_Auto_Recovery and Output_Enable.
Structure of configuration data for TBEN-LG-8DIP-8DOP, including abbreviations.
Configuration data structure for TBEN-LG-16DIP, detailing byte and bit assignments.
Configuration data structure for TBEN-LG-16DOP, showing byte and bit mapping.
Configuration data structure for TBEN-LG-16DXP, detailing byte and bit assignments.
Configuring TBEN-LG-16DIP using the Generic Ethernet Module in RSLogix5000.
Steps to configure TBEN-LG-16DOP with the Generic Ethernet Module profile.
Configuring TBEN-LG-8DIP-8DOP using the Generic Ethernet Module profile.
Steps for configuring TBEN-LG-16DXP with the Generic Ethernet Module profile.
Overview of the TBEN web server's home page, showing device and network information.
Procedure for logging into the TBEN web server as an administrator.
Modifying Ethernet port settings and device IP address via the web server's network configuration page.
Enabling/disabling features and managing device settings through the station configuration page.
Viewing historical diagnostics content from the TBEN device.
Monitoring current status and statistics of TBEN device Ethernet ports.