TBEN-LG EtherNet/IP
TM
Configuration Guide
TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 20
Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us
BOOTP/DHCP Mode (300/400)
The TBEN rotary switches, when set to 300 or 400, allow for IP address assignment as follows:
− Set the rotary switches to 300 to enable BOOTP mode and power cycle the device
− Set the rotary switches to 400 to enable DHCP mode and power cycle the device
− Run BOOTP or DHCP utility and assign IP address
− Set the rotary switches either to 500 (PGM mode) or to a number that matches the last
octet of the assigned IP address (e.g. 125)
− Power cycle the device
Note:
When the device is set to 500 (PGM) mode, its IP address can be further changed using
either the IP Address Tool or WEB page.