4
Static Electricity
Before handling any internal components, discharge static electricity by touching a grounded surface.
Wear a grounding wrist strap and stand on a grounded static protection mat during installation
Limit movement during installation to reduce static buildup.
Transport components in static-shielded containers.
Compliance
The iSTAR Ultra G2 SE must be installed within the protected premises.
When purchased separately, the iSTAR Ultra G2 SE modules must be installed in an enclosure which has an electrically
supervised tamper switch to maintain UL compliance.
For Proprietary Burglar Alarm installations, the iSTAR Ultra G2 SE must be installed in accordance with UL 681 - Standard
for Installation and Classification of Burglar and Hold-Up Alarm Systems.
Power
The iSTAR Ultra G2 SE is powered by a UL 603 or UL 2610 listed External Power Supply.
The Software House apS or a Power over Ethernet (PoE++) injector with a UL listed surge protector, evaluated to UL 1449,
can be used as an External Power Supply.
A PoE++ module can be used with UL 294, UL 603, and UL 2610 listed injectors.
The iSTAR Ultra G2 SE must be permanently wired to mains electricity without switches that could be used to interrupt the
electricity supply. For more information on installations using PoE modules, see the
iSTAR Ultra G2 Controller Installation and
Configuration Guide
.
NOTE
Power-limited PoE injectors, which are UL 294, UL 603, and UL 2610 listed can be used with PoE++ modules.
IEEE 802.3 (AT or AF) compliance was not verified to UL294.
PoE installations are UL listed for Mode B only.
Grounding
Ensure that the iSTAR Ultra G2 SE controller is properly connected to an earth ground at any of the ground studs.
Ensure that the shield wires (including the ACM-SE and GCM)are grounded to the nearest ground connection at one end of
the cable.
Ethernet Connection
2 Ethernet ports onboard - supports 10/100/1000 Base-T Ethernet connections.
Built-in LEDs indicate the Ethernet Link and Receive Data signals.
Encryption
TLS v1.3 encryption in Ultra G2 or Edge G2 mode.
TLS v1.2 encryption and unencrypted option in Ultra mode.