3
Specifications and Requirements
Specifications
iSTAR Ultra G2 SE Specifications
Environmental
Operational Temperature 32° F ( C) to 120° F (4 C)
Electrical (GCM)
Electrical Input 12 VDC (3 A) or 24 VDC (1.5 A)
Electrical (ACM-SE)
VIN
Electrical Input Up to 12 VDC (9 A) or 24 VDC (3 A)
RS485
Electrical Output 12 VDC (1.2 A) per port.
Wiegand
Electrical Output 12 VDC (0.8 A) per port.
Relay Ports (Dry - Primary)
Electrical Output Primary: 30 V AC/DC (5 A maximum)
Table 1:Environmental and Electrical Specifications
NOTE
Voltage tolerances are 85% - 100%of listed specifications.
Safety Information
Life Safety Requirement
A fail-safe mechanism override must be installed at each card reader exit to allow people to leave the secure area in case of
electromechanical device failure.
Disconnect all power before modifying any jumper settings or the wiring to, or within, the iSTAR Ultra G2 SE.