EQUIPMENT: T1200-C
PUBLICATION: MARINEC-P-A
ISSUE No. & DATE: 3 02/14
© 2014 Thorn Security Ltd PAGE 3 of 67
Registered Company: Thorn Security Ltd. Registered Office: Dunhams Lane Letchworth Garden City Hertfordshire SG6 1BE
17.5 CONFIGURE NON-LATCHING ZONES ............ 45
17.6 CONFIGURE INTRINSICALLY SAFE ZONES .... 45
17.6.1 MIXED I.S. AND NON-I.S. ZONES ............. 45
17.7 THE DELAY MODE FEATURE ....................... 46
17.7.1 SELECTION OF OUTPUTS TO BE DELAYED. 46
17.8 SELECTABLE ZONAL OR GENERAL ALARM
SOUNDER OPERATION ................................ 46
17.9 PULSE NON-ALARM ZONES ........................ 46
17.10 ALARMS IN CREW AREAS ............................ 46
17.11 DELAY RESTART DIL SWITCH ..................... 46
17.12 SELECTABLE MUSTER/MANUAL FIRE ALARM
SOUNDER OPERATION ................................ 46
17.13 INHIBIT FIRE PROTECTION ON NON-LATCHED
ZONE DIL SWITCH ..................................... 47
17.14 DELAY ALARM SILENCE AND RESET CONTROLS
DIL SWITCH ............................................... 47
17.15 DELAY ON AUTO DIL SWITCH .................... 47
17.16 ALARMS ON EVAC ONLY DIL SWITCH .......... 47
17.17 SILENCE BEFORE RESET DIL SWITCH ......... 47
17.18 CONTINUOUS OR PULSED SOUNDER
OPERATION DIL SWITCH ............................ 47
17.19 SILENT ZONE TEST DIL SWITCH ................. 47
17.20 BUZZER DISABLE DIL SWITCH .................... 47
17.21 LATCHED FAULTS DIL SWITCH .................... 47
17.22 REPEATER CONFIGURATION ....................... 47
17.23 OUTPUT RELAY CONFIGURATION ................ 47
17.24 EARTH FAULT MONITORING ......................... 48
18. PANEL REPEATERS ........................................... 48
18.1 REPEATER USER INDICATIONS .................... 49
18.2 REPEATER USER CONTROLS ...................... 49
19. CIRCUIT CONNECTION DETAILS ......................... 50
19.1 T1204 (C1626) 4-ZONE PANEL TERMINATION
DETAILS .................................................... 50
19.2 T1216-C AND T1232-C (C1627) 16-ZONE
MOTHERBOARD TERMINATION DETAILS ....... 50
19.3 32-ZONE EXPANSION BOARD TERMINATION
DETAILS .................................................... 50
19.4 AUXILIARY SUPPLY ..................................... 51
19.5 FIRE PROTECTION, FIRE OUTPUT AND FAULT
OUTPUT SIGNAL OUTPUTS ......................... 51
19.6 USE OF AUXILIARY INPUTS .......................... 51
19.7 SOUNDER CIRCUITS ................................... 51
19.8 ELECTRICAL DESIGN OF DETECTION ZONES 53
19.8.1 MAXIMUM NUMBER OF DEVICES ON A ZONE
................................................................. 53
19.8.2 INTRINSICALLY SAFE ZONES .................... 53
19.9 REPEATER PANEL AND REPEATER MUSTER
WIRING ...................................................... 55
20. MECHANICAL, ELECTRICAL AND ENVIRONMENTAL
SPECIFICATION ................................................. 56
21. T1200-C INPUT AND OUTPUT SPECIFICATION .... 59
22. APPENDIX ......................................................... 62
22.1 EN54 OPTIONAL FUNCTIONS WITH
REQUIREMENTS ......................................... 62
22.2 ANCILLARY FUNCTIONS NOT REQUIRED BY
EN54 ........................................................ 62
22.3 POWER SUPPLY LOAD CALCULATION .......... 63
22.4 MINIMUM STANDBY BATTERY CAPACITY
CALCULATION ............................................ 63
22.5 A1466 INTERFACE RELAY .......................... 65
22.6 PANEL CONFIGURATION DESIGN CHART ...... 66
1. List of Figures
FIGURE 1 – 4-ZONE PANEL ENCLOSURE EXTERNAL
VIEW
........................................................ 5
FIGURE 2 – CONSOLE MOUNT PANEL ENCLOSURES
EXTERNAL VIEW
....................................... 6
FIGURE 3 – BATTERY BOX ......................................... 7
FIGURE 4 – T1204 PANEL – GENERAL ASSEMBLY ..... 10
FIGURE 5 – T1216-C PANEL – GENERAL ASSEMBLY . 11
FIGURE 6 – T1232-C PANEL – GENERAL ASSEMBLY . 12
FIGURE 7 – T1216R-C REPEATER – GENERAL
ASSEMBLY ............................................. 15
FIGURE 8 – C1626 MOTHERBOARD LAYOUT .............. 21
FIGURE 9 – C1627 MOTHERBOARD LAYOUT .............. 22
FIGURE 10 – C1632 16-ZONE EXPANSION BOARD ..... 23
FIGURE 11 – REAR RIGHT HAND SIDE OF DISPLAY PCB
............................................................. 23
FIGURE 12 – C1714 VDR INTERFACE MODULE ........ 24
FIGURE 13 – C1630 OUTPUT EXPANSION INTERFACE
............................................................. 34
FIGURE 14 – C1631 REPEATER INTERFACE BOARD .. 34
FIGURE 15 – C1665 MUSTER INTERFACE BOARD ..... 34
FIGURE 16 – PS40-1-09 1.5 AMP 24VOLT DC POWER
SUPPLY LAYOUT .................................... 38
FIGURE 17 – PS136-1-09 4 AMP 110/230VAC POWER
SUPPLY LAYOUT .................................... 38
FIGURE 18 – REPEATER DISPLAY ............................. 48
FIGURE 19 – C1626 FIELD TERMINATIONS ................ 50
FIGURE 20 – C1627 FIELD TERMINATIONS ................ 50
FIGURE 21 – C1632 17-32 ZONE EXPANSION BOARD
FIELD TERMINATIONS
.............................. 50
FIGURE 22 – AUXILIARY I/P CONNECTION DETAIL....... 51
FIGURE 23 – ALARM CIRCUIT CONFIGURATION .......... 51
FIGURE 24 – FIRE PROTECTION, FIRE AND FAULT
SIGNAL OUTPUT CONNECTIONS .............. 52
FIGURE 25 – RESET RELAY CONTACT CONNECTION
DETAILS
................................................. 52
FIGURE 26 – TYPICAL T1200-C
WIRING DIAGRAM .... 54
FIGURE 27 – REPEATER WIRING DIAGRAM ............... 55
FIGURE 28 – MUSTER INTERFACE WIRING DIAGRAM . 55
FIGURE 29 – A1466 INTERFACE RELAY SPECIFICATION
............................................................. 65
2. List of Tables
TABLE 1 – MOTHERBOARD DIL SWITCH
CONFIGURATION DESIGN/RECORD .......... 66
TABLE 2 – ZONE CONFIGURATION DESIGN/RECORD .. 67
TABLE 3 – OUTPUT DELAY CONFIGURATION
DESIGN/RECORD ................................... 67