DocNo.FM0548issueBPage11
15.HOWTOCREATENEW
WhentheAltecResponseleftthefactoryitwasprogrammedtorecogniseallsensorsintheAltecrangeatthattime–seelist
insidefrontcover.IfyouattempttolearnanewsensoranditisnotbeingrecognisedthenyoucanaddittotheAltec
Response
memoryusingthe“CreateSensor”menuoption.
FromtheMainMenudisplayscrolldownto Create Sensor andpresstheENTERkey.
Main Menu V1.00A
ThedisplaywillchangetoshowCreateSensoroptions;
Create Sensor
Usethekeystoselectthenextavailable EMPTY SLOT (max12).
PresstheENTERkeythenpressthe&keystogethertoclearthe EMPTY SLOTprompt.
Usethekeystoenterthefirstcharacterofthenewdevicetypebeingadded,selectfrom0‐
9A‐ZSPACE.
Usethekeystomovebetweencharacters.PresstheENTERkeywhendone.
Pressthekeytoselect BS Code: 00 thenpresstheENTERke y.Usethekeystoselectthefirstdigit(0‐9)ofthe
BScodeandusethekeystomovebetweendigitsthenpresstheENTERkey.Note:theBScodeisthefirst
2digitsofthe
8digitIDprintedonthedevicelabel.
Create Sensor
Pressthekeytoselect BS Status 1: 00 thenpresstheENTERkey.Usethekeystoselectthefirstdigit(0‐9)
oftheBSStatus1andusethekeystomovebetweendigitsthenpresstheENTERkey.Note:theBSStatus1
(alarm)is
normally09.
Pressthekeytoselect BS Status 2: 00 thenpresstheENTERkey.Usethekeystoselectthefirstdigit(0‐9)of
theBSStatus2andusethekeystomovebetweendigitsthenpresstheENTERkey.Note:theBSStatus2is
normally00.
Toexitthemodeselect Exit thenpresstheENTERkey.
Note:ifyouareunsure,pleasecontactTynetec’scustomersupportdepartmentfordetailsoftheBScodesandstatus’sfor
newdevices.