PAGE 5 OF 27 0417 IH-1649
OPERATION CONTINUED
FUNCTIONS
MANUAL ACCUMULATION
When the scale is set for manual accumulation:
1. Press the ACC key
Acc
to store the displayed weight
in the memory when the weight is stable.
2. Display shows ACC 1 and then the total stored in
memory for two seconds before returning to normal.
3. Remove the weight and allow the scale to return to
zero, then add a second weight.
4. Press ACC
Acc
, the display shows
ACC 2
and the new total.
5. Continue to remove and add weights and press
ACC
Acc
until all weights have been added.
6. To view the totals in memory, press ACC
Acc
when
the scale shows zero. The display shows the total
number of items ACC xx and the total weight and
then returns to zero.
To clear the memory:
1. Press ACC
Acc
to display the totals.
2. Press the FUNC/C key
Func
to clear the memory.
NOTE: ACC function is only available when the
stable indicator "O" is on.
AUTOMATIC ACCUMULATION
When scale is set for automatic accumulation:
1. Add a weight to the scale. The beeper sounds when
the weight is stable to indicate the weight is added.
Remove the weight.
2. Display shows ACC 1 and totals the memory when
the scale returns to zero.
3. Add the next weight to continue the process.
NOTE: While a weight is on the scale, you can
also press ACC to store the value immediately.
In this instance, the scale will not store the
value when the weight is removed.
4. Press ACC
Acc
to display the accumulated totals.
NOTE: The scale must return to zero or display
a negative number before another sample
can be added to the memory. More items can
be added and ACC pressed again, up to 99
entries or until you exceed the weight capacity
displayed.
5. To return to normal weighing mode, turn AU off.
To set functions, press the FUNC
Func
and ACC
Acc
keys
at the same
time. Scroll through functions by pressing
%/<
%
or LIMIT/>
Limit
– the scale will go through the
functions in this order:
CHANGE SCALE WEIGHT INCREMENT
To minimize effects of vibration, wind or other conditions:
• Example: If scale normally weighs in increments of
0.5g, the value can be changed to 1.0g or 2.0g to
get a more stable reading.
1. Display shows Inc xx. The first value shown is the
default weight increment.
2. Press the TARE/^ key
Tare
to change the default.
3. Press ZERO/ENTER
Zero
to set the new weight increment.
BACKLIGHT CONTROL
Backlight is set to operate automatically, turning off
when the scale is not being used. Turning the backlight
off helps maximize battery life.
1. Press TARE/^
Tare
to select EL On (manual on),
EL Au (automatic on/off), or EL Off (turns off backlight)
2. Press ZERO/ENTER
Zero
to set your selection.
ACCUMULATED TOTAL
Scale can be set to accumulate manually or automatically.
(Refer to ACCUMULATED TOTAL in OPERATION section.)
CHANGE THE BAUD RATE
Display shows b xxx this is the current baud rate.
1. Press TARE/^
Tare
to select: 600bps, 1200bps,
4800bps or 9600bps.
2. Press ZERO/ENTER
Zero
to set your selection.
AUTO ZERO RANGE TRACKING
Set to 0.5d, 1d, 2d and 4d.
1. Press TARE/^
Tare
to select.
2. Press ZERO/ENTER
Zero
to set your selection.