LISA mounting option
with LISA paste mask
ANT pad
TOBY mounting option
with TOBY paste mask
ANT pad
SARA mounting option
with SARA paste mask
ANT pad ANT pad
LARA mounting option
with LARA paste mask
LISATOBY SARA LARA
 
Figure 98: Nested Design concept description: TOBY, LISA, SARA modules alternatively mounted on the same application board 
The voltage level of all the digital interfaces of SARA and LISA modules is 1.8 V: this allows the direct connection 
from a 1.8 V external device (e.g. application processor) to all the modules. 
The following sections explain in detail all the points to consider during the migration between LISA and SARA 
designs, implementing or not a nested design 
For further details regarding SARA-G3 and LISA characteristics, usage, or settings, see the related module data 
sheet [1], [4], [5], [6], system integration manual [7], [8], and the AT commands manual [3], [9]. 
 
A.2  Checklist for migration 
Have you chosen the optimal SARA-G3 module? 
  For quad-band GSM/GPRS, full feature set, select the SARA-G350 module. 
  For dual-band GSM/GPRS, full feature set, select the SARA-G340 module. 
  For quad-band GSM/GPRS, reduced feature set, select the SARA-G310 module. 
  For dual-band GSM/GPRS, reduced feature set, select the SARA-G300 module. 
Check SARA-G3 modules hardware requirements 
  Check power capabilities of the external supply circuit: SARA-G3 modules require large current pulses in 
connected mode as well as LISA-U2 series modules when a 2G call is enabled. LISA-C2 series modules 
do not require large current pulses due to the CDMA channel access technology. 
  Check  supported bands for  proper antenna circuit  development:  SARA-G3  modules frequency  ranges 
are within LISA-U2 modules ranges, but LISA-C2 modules range is quite different. 
  Check  antenna  detection  requirements:  SARA-G340  and  SARA-G350  modules  provide  the  antenna 
detection function implementing an external application circuit between ANT_DET and ANT pins. 
  Check  the  module  power-on  requirements:  Table  67  and  relative  section  summarize  differences 
between SARA-G3 and LISA modules. 
  Check the module requirements to enter low power idle mode: SARA-G300 and SARA-G310 modules 
require a 32 kHz signal at EXT32K input, which for example can be provided by the 32K_OUT output.