SARA-G3 and SARA-U2 series - System Integration Manual 
UBX-13000995 - R26    Appendix  
    Page 197 of 217 
  Check serial interface requirements: SARA-G3 modules provide UART interface for AT command, data 
communication, mux functionality, FOAT and provide auxiliary UART interface for AT command
50
, GNSS 
tunneling
50
, FW upgrade using the u-blox EasyFlash tool and for diagnostic purposes. 
  Check analog audio requirements: SARA-G340 and  SARA-G350 modules do  not provide DC blocking 
capacitors at the MIC_P / MIC_N input pins and provide supply output and local ground for an external 
microphone at the MIC_BIAS / MIC_GND pins. 
  Check  digital  audio  requirements:  SARA-G340  and  SARA-G350  modules  provide  a  4-wire  1.8  V 
interface supporting PCM and Normal I2S modes, master role and fixed sample rate. 
  Check internal active pull-up / down values at digital interface input pins and the current capability of 
digital interface output pins, since they are slightly different between SARA-G3 and LISA modules. 
Check SARA-G3 modules software requirements 
  Not  all  of  the  functionalities  available  with  LISA  modules  are  supported  by  all  the  SARA-G3  modules 
versions. SARA-G300 and SARA-G310 modules do not support: 
o  Audio interfaces, DDC (I
2
C) interface, Antenna detection interface, GPIOs 
o  Low power idle mode, if a 32 kHz signal at EXT32K input pin is not provided 
o  TCP/IP, UDP/IP, FTP, HTTP 
o  GNSS via Modem, AssistNow clients, Hybrid positioning and CellLocate
®
 functionalities 
o  Jamming detection 
 
  
50
 SARA-G3 modules product versions “00” and “01” do not support AT command mode and GNSS tunneling over the Auxiliary UART.