  SARA-G3 modules’ autobauding and SARA-U2 modules’ one-shot autobauding are enabled by default. 
The following baud rates can be configured by AT command (see the u-blox AT Commands Manual [3], +IPR): 
  1200 bit/s  
  2400 bit/s 
  4800 bit/s 
  9600 bit/s 
  19200 bit/s 
  38400 bit/s 
  57600 bit/s 
  115200 bit/s, default value when the autobauding or the one-shot autobauding are disabled 
  230400 bit/s 
  460800 bit/s 
  921600 bit/s 
 
  1200  bit/s,  230400  bit/s,  460800  bit/s  and  921600  bit/s  baud  rates  are  not  supported  by  SARA-G3 
modules. 
  460800 bit/s and 921600 bit/s baud rates cannot be automatically detected by SARA-U2 modules. 
 
SARA-G3 modules support the automatic frame recognition in conjunction with autobauding. 
SARA-U2 modules support the one-shot automatic frame recognition in conjunction with one-shot autobauding. 
 
  SARA-G3 series modules’ automatic frame recognition and SARA-U2 series modules’ one-shot automatic 
frame recognition are enabled by default, as autobauding and one-shot autobauding. 
 
The  following  frame  formats  can  be  configured  by  AT  command  (see  the  u-blox  AT  Commands  Manual  [3], 
+ICF):  
  8N1 (8 data bits, no parity, 1 stop bit), default frame configuration with fixed baud rate 
  8E1 (8 data bits, even parity, 1 stop bit) 
  8O1 (8 data bits, odd parity, 1 stop bit) 
  8N2 (8 data bits, no parity, 2 stop bits) 
  7E1 (7 data bits, even parity, 1 stop bit) 
  7O1 (7 data bits, odd parity, 1 stop bit) 
 
Figure 25 describes the 8N1 frame format, which is the default configuration with fixed baud rate.