Measurement Range: 25 to 30,000 feet
26ga to 4/0ga
250MCM to 500MCM
Accuracy: Ambient Temperature: 65˚ to 75˚F
< 30ft: ±6 LSD
> 30ft: ±(2% of reading + 3 LSD)
Ambient Temperature: <65˚ and >75˚F
< 30ft: ±6 LSD
> 30ft: ±(3% of reading + 3 LSD)
LSD = least significant digit
Resistance: 0 to 65Ω (±2% of reading)
Operating Temperature: 32˚ to 104˚F
Operating Humidity: 20% to 80% RH
Storage Temperature: 0˚ to 120˚F
Auto power off: After 5 minutes (approx.)
Battery Life: Depends on use. Typically 40 hours.
Extended measurements times can lower battery life to no less than 6 hours.
WARNING: This meter is NOT designed to measure less than 25ft cable.