16 GB/IE/NI/CY/MT
z Cleaning
Attention: The device must
not be submerged in water.
There is a risk of injury due
to electric shock if moisture
enters the device.
Do not use cleaners or solvents.
These could damage the device
ERROR 4 Self test failed Disconnect from the car and mains.
Then start the charging process again.
If the fault should occur again, return
the mobile charging station
1
to the
dealer for repair.
ERROR 5 Under voltage
(input voltage
below 185 V)
Disconnect from the car and mains.
Wait until the mains voltage rises to
over 195 V. Then start the charging
process again.
ERROR 6 Over voltage
(input voltage is
over 275 V)
Disconnect from the car and mains.
Wait until the mains voltage drops to
below 265 V. Then start the charging
process again.
ERROR 7 Internal component
fault (relay)
Disconnect from the car and mains.
Return the mobile charging station
1
to the dealer for repair.
ERROR 8 The temperature on
the Mains plug
7
is too high.
(temperature in the
mains plug
7
is
over 80°C)
Disconnect from the car and mains.
Wait until the temperature in the mains
plug has dropped below 70 °C.
Then start the charging process again.
ERROR 9 Possible fault in
the car electronics
(diode)
Disconnect from the car and mains.
Then start the charging process again.
ERROR 10 Short circuit cables
(CP to PE)
Disconnect from the car and mains.