7
(11) Ingestion of rubbish and dust in the air entering the pump will interfere with its proper
function. If the air is likely to contain rubbish or dust, a filter should be fitted to the inlet to
protect the pump.
(12) Pay attention not to inhale the steam or corrosive gas that may damage human body.
Operation
(13) Ensure that the pump is used within an ambient temperature range of 5 - 40°C.
Use at high temperatures will dramatically reduce the life of the pump.
(14) Back pressure at the outlet while the pump is starting may overload the motor.
(15) The thermal protector operates when the pump reaches a very high temperature. Touching
the pump in this condition may result in burns.
(16) To maintain the performance of the pump, always ensure that it is cleaned internally after
use.
Clean by ingesting clean air for 3~5 minutes under no-load conditions.
Maintenance and Repair
(17) The fine clearances used in this pump require skill in its assembly. If a repair technician is
unavailable, replacement of all consumables should be left to the manufacturer’s service
division.