Model UT231: OPERATING MANUAL
31
G. Power Factor (PF = W / VA)
Range
0.3~1
(capacitive or inductive)
0.3~1
(capacitive or inductive)
Accuracy
0.022
Resolution
0.001
Measuring Condition
The minimum measuring current 10A
The minimum measuring voltage 45V
Measuring current less than 10A OR
Measuring voltage less than 45V
Remarks:
Allowable maximum overload protection voltage: 600V RMS
Allowable maximum overload protection current: 1000A RMS
H. Phase Angle (PG=acos (PF))
Accuracy
1
o
Resolution
1
o
Measuring Condition
The minimum measuring current 10A
The minimum measuring voltage 45V
Measuring current less than 10A OR
Measuring voltage less than 45V
For reference only
Range
0
o
~360
o
0
o
~360
o
For reference only