EasyManua.ls Logo

UNI-T UTD2025C User Manual

UNI-T UTD2025C
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background image
9
2
Technical Indicator
s
Samplin
g
Sampling mode
Real-time
Equivalent
Samplin
g
rate
UTD2000C/3000
C
UTD2000E/3000E
UTD2052C
L
UTD2052CEX/UTD2102CEX
500M
S
/s
500M
S
/s
1GS/s
1GS/s
25GS/s
25GS/s
50GS/s
50GS/s
A
verage
value
N can be selected from 2, 4, 8, 16, 32, 64, 128 and 256 after sampling all channels for
N t imes at the same time
.
Note: Real-time sampling rate is 250MS/s without equivalent sampling for UTD2025C, UTD3025C and
UTD2025CL
.
Oper ating Man ual for UTD2000/ 3000

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the UNI-T UTD2025C and is the answer not in the manual?

UNI-T UTD2025C Specifications

General IconGeneral
BrandUNI-T
ModelUTD2025C
CategoryTest Equipment
LanguageEnglish

Summary

Introduction and Safety Information

General Safety Overview

Essential safety precautions to prevent injury and product damage.

Safety Terms and Symbols

Explains hazardous terms and symbols used in the manual and on the product.

User Guideline

General Inspection

Inspect instrument for damage and check fittings upon arrival.

Probe Compensation

Adjust probe capacitance for accurate waveform display using compensation signal.

Automatic Waveform Setup

Automatically adjusts vertical deflection, time base, and trigger for optimal display.

Instrument Setup

Vertical System Setup

Configure coupling, bandwidth, probe factor, and phase for vertical channels.

Trigger System Setup

Configure trigger source, gradient, mode, coupling, and sensitivity for precise triggering.

Automatic Measurement

Measure waveform parameters like voltage, time, frequency, and amplitude automatically.

Application Examples

Capture of Single Signal

Capture transient or aperiodic signals like pulses using appropriate trigger settings.

Reduce Random Noise

Filter noise and improve waveform clarity using trigger coupling and sampling modes.

Pass/Fail Detection

Configure instrument to check if signals meet predefined tolerance limits.

System Prompt and Troubleshooting

System Prompts

Explains on-screen prompts indicating instrument status or operational limits.

Troubleshooting

Diagnoses and resolves common issues like no display or unstable waveforms.

Appendices

Technical Indicators

Lists detailed technical specifications and performance characteristics of the oscillograph.

Maintenance and Cleaning

Provides instructions for cleaning and maintaining the instrument for longevity and performance.