EasyManua.ls Logo

Unical ALKON 50 c - Gas and Condensation Connections

Unical ALKON 50 c
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
ENGLISH
Installation Instructions
ALKON 50 C ALKON 70 C
M FLOW G 1’’ G1 ¼’’
R RETURN G 1’’ G1 ¼’’
G GAS G ¾’’
S.cond CONDENSATION DRAIN
Svs SAFETY VALVE DRAIN
Provide a drain pipe with funnel and a trap that
lead to a suitable drain, in correspondence of Svs.
This drainage must be controlled on sight.
If this precaution is not taken, triggering of the safe-
ty valve can cause damage to persons, animals
and objects, for which the manufacturer cannot
be held responsible..
Condensation outlet, pipe to be connected to the drain-
age system
The connection between the appliance and the do-
mestic waste system must be made in compliance
with the specic reference standards..
3.7 - CONNECTION
Danger!
The gas connection must be carried out only by
a qualied installer who must respect and apply
that foreseen by relevant laws in force in the local
prescriptions of the supply company. Incorrect in-
stallation can cause damage to persons, animals
and objects for which the manufacturer cannot be
held responsible.
If you smell gas:
a) Do not operate electric switches,
the telephone or any other object that
may cause sparks;
b) Immediately open doors and
windows to create air current
to purify the room;
c) Shut the gas cocks.
Condensation drain
The boiler, during the combustion process, produces conden-
sation that, through pipe “A”, ows into the trap.
The condensation that forms inside the boiler ows into a suitable
drain via pipe “B”.
Danger!
Before commissioning the appliance:
- check that the trap is assembled
properly
- ll the trap and check that
the condensation is drained properly
If the appliance is used with an empty condensa-
tion drain trap, there is an intoxication hazard due
to the release of exhaust gasses..
Danger of burns!
Attention to contact with ow pipe M and with
hot water outlet pipe C (if boiler with DHW kit).