HT630 Product Reference Guide
Chapter 4 Built-in Application- FormCaching
The system of terminal includes a built-in application, FormCaching. It allows you to create a data entry
application from specifying field prompt, type, length, input method and delimiter, etc. without writing
program and loading to the terminal.
4.1 Specification of FormCaching
DATA FIELD DEFINITION: maximum field number=8
Category Range Description
1 FIELD PROMPT max.16
characters
set field prompting
2 MIN/MAX
DATA LENGTH
1-32 set minimum field length
and maximum field length
3 DATA TYPE 1.NUMERIC
2.ALPHANUM
numeric data (0~9) or
alphanumeric data
(20H~FCH)
4 DEVICE TYPE 1.KEY ONLY
2.SCAN ONLY
input by keyboard only,
bar code scanning only or
both 3.BOTH
DATA RECORD DEFINITION
Category Range Description
5 BETWEEN
FIELD
1.Append screen specify to clear or append
screen between two fields
2.Clear screen
1., 2.; 6 FIELD
DELIMITER
assign field delimiter
3.Space
4.Tab
1.CR 2.LF 7 RECORD
DELIMITER
assign record delimiter
3.CRLF
8 DATE
STAMP
FIELD
1:NONE
2.YYYYMMDD
3.MMDD
4.MMDDYYYY
specify format of Date
stamp
5.DDMM
6.DDMMYYYY
9 TIME STAMP
FIELD
1:NONE 2.HHMM specify format of Time
stamp
3.HHMMSS
10 FIELD
DELAY
0-6 specify time delay
between each record
input in second