EasyManua.ls Logo

Unitech MS350 - MSI;Plessey Barcode Settings

Unitech MS350
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90
MSI/plessey
Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Checksum2
(Optional)
Checksum Verification: The MSI/Plessey has one or two
optional checksum digits. The checksum is presented 3
kinds of method Mod10, Mod10/10 and Mod 11/10. The
checksum1 and checksum2 will be calculated as the sum
module 10 or 11 of the data digits.
Checksum Transmission: By setting Enable, checksum1
and checksum2 will be transmitted upon your selected
checksum verification method.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Checksum
Verification
Disable
Mod 10
Mod 10/10
Mod 11/10
00
01*
02
Program

Table of Contents

Other manuals for Unitech MS350

Related product manuals