Do you have a question about the Unitech MS100 and is the answer not in the manual?
Wavelength | 660 nm |
---|---|
Sensor type | Photo diode |
Tilt reading angle | 45 - 90 ° |
Dimensions (WxDxH) | 140 x 30 x 23 mm |
Cable length | 1.80 m |
Standard interfaces | RS-232 |
Power consumption | 800 mA |
Power requirements | 5V DC |
Product color | Black, Blue |
Housing material | Plastic |
Storage temperature (T-T) | -20 - 60 °C |
Operating temperature (T-T) | 0 - 50 °C |
Operating relative humidity (H-H) | 20 - 85 % |
Weight | 76.5 g |
---|
Describes MS100A (external decoder), MS100-2 (RS232, ASCII output), MS100-3 (AT keyboard wedge), MS100-3PS2 (PS/2 keyboard wedge), and MS100-4 (USB, HID output).
Details launching the SCM software, its interface, and the function of its icons.
Explains the procedure for downloading configured settings to the scanner via SCM.
Guides on uploading scanner settings from the scanner to the SCM.
Describes how to navigate and edit scanner attributes (e.g., Device, Beeps and Delays) within SCM.
Explains the "Device" setting, specifically the "Device ID" for identifying the connected device.
Details attributes for "Beeps and Delays": Beep Tone, Intercharacter Delay, and Interblock Delay.
Explains "Function Code" for outputting function codes and "Caps-Lock" for controlling character case.
Covers Language sets, Wand Emulation output (0s and 1s), and minimal width duration.
Details Polarity of Idle Condition and the Use Numeric Keypad setting.
Covers Baud Rate, Parity, Data Bit, Handshaking, ACK/NAK, and BCC Character settings.
Explains Time Out for ACK/NAK and options for Data Direction.
Describes user-definable Receive Terminators and their pre-defined characters.
Details Terminator options and the Use Code ID function for identifying bar code types.
Explains the Double Verification feature for ensuring scan accuracy.
Describes various Scanning Modes (Trigger, Flashing, etc.) and Label Types (Positive/Negative).
Covers the Aim Function for laser scanners to provide an aiming aid.
Details Aiming Time and the insertion of Preamble/Postamble characters.
Details parameters for Code 39: Enabled, Code ID, Type, Check Digit, Send Start/Stop, Min/Max Length.
Details parameters for Interleaved 2 of 5: Enabled, Code ID, Fix Length, Check Digit, Min/Max Length.
Explains parameters for Standard 2 of 5 and Toshiba Code: Enabled, Fix Length, Check Digit, Min/Max Length.
Details parameters for Code 32 (Code ID, Leading/Tailing) and EAN 128 (Enabled, Code ID, Field Separator).
Lists parameters for Code 128: Enabled, Code ID, Minimum/Maximum Length.
Explains MSI/Plessey Code parameters: Enabled, Code IDs, Check Digit Formula, Min/Max Length.
Details parameters for Code 93: Enabled, Code ID, Minimum/Maximum Length.
Details Codabar parameters: Enabled, Code ID, Send Start/Stop, Check Digit, CLSI Format, Min/Max Length.
Explains UPC-A parameters: Enabled, Code ID, Send Leading/Check Digit.
Details UPC-E (Zero Expansion, NSC) and EAN-13 (Bookland EAN) parameters.
Explains EAN-8 parameters: Enabled, Code ID, Send Leading/Check Digit.
Details Code 11 (Check Digit, Min/Max Length) and Delta Code (Check Digit) parameters.
Explains Supplement Code options for UPC-E, ISBN, EAN-13: Two/Five Supplement Code, Must Present, Space Separator.
Explains Label Code IV and V parameters: Enabled, Code ID, Send Check Digit.
Introduces Data Editing and the "Define Formula" box with Qualifier and Modifier sections.
Explains the Qualifier section for defining bar code conditions (type, length, character strings).
Details the Modifier section options: "From Original", "Add New", and "Delete".
Explains how to "Add New" characters and "Delete" modifier strings in data editing.
Details "Move Up/Down" for modifiers and the use of special characters in data editing.
Describes arranging formulas in sequence for optimal data editing.
Explains the purpose and implementation of an "Everything Else" formula in data editing.
Explains the concept of parameter groups and how to modify them using scanner input bar codes.
Mentions using Quick Setup bar codes as an alternative programming method.
Shows bar codes for Device Type (PC AT, USB, etc.) and Inter-Character Delay (1ms, 20ms).
Displays bar codes for Scanner Mode (Trigger, Flash), Code ID (No, Yes), and Terminator (Enter, Field Exit).
Shows bar codes for Beep levels (None, Medium) and Scan Code (U.S., Alt Key).
Displays bar codes for EAN-8, UPC-A, EAN-13, UPC-E settings like Default, Leading Digit, Check Digit.
Shows bar codes for Factory Default reset and Supplemental Code settings.
Instructions for entering Group 1 for device selection and default settings.
A chart mapping Device IDs to their corresponding Device Types for scanner configuration.
Bar codes to set Group Default or Factory Default configurations for the scanner.
Shows bar codes for setting Beep Tone (None, High) and Interblock Delay (0 ms, 5 seconds).
Displays bar codes for setting Intercharacter Delay durations (0 ms, 100 ms).
Shows bar codes for Function Code (Off, On) and Caps-Lock (Auto Trace, Lower Case, Upper Case).
Displays bar codes for Language (U.S., German) and Numeric Keypad Digits (Disable, Enable).
Shows bar codes for Baud Rate (9600), Parity (None), and Data Bit (8) settings.
Displays bar codes for Handshaking (Ignore), ACK/NAK (Off), and BCC Character (Off) settings.
Details Time Out (1 second) and Data Direction (Send to Host) settings via bar codes.
Shows bar codes for Terminator (Enter), Code ID (Enable), and Double Verification (Off, 1-7 times).
Displays bar codes for Scanning Mode (Trigger, Multiscan, etc.).
Details Label Type (Positive), Aim Function (Enable), and Data Length Send (Enable) settings.
Explains how to insert Preamble or Postamble sequences using specific bar codes.
Details parameters for Code 39, ITF, and Standard 2 of 5 / Toshiba Code.
Details parameters for Code 32, Telepen, and UCC/EAN 128 symbologies.
Instructions for defining EAN128 fields separator and double label separator.
Details parameters for Code 128, MSI/Plessey, Code 93, and Code 11 symbologies.
Details parameters for Codabar and Label Code IV/V symbologies.
Instructions on defining minimum and maximum acceptable bar code data length.
Details parameters for UPC-A, UPC-E, EAN-13, and EAN-8 symbologies.
Details parameters for Supplement Code and Delta Code options.
Explains using Input ID to select specific bar code symbologies for data editing.
Describes using LEN, MIN, MAX parameters to select bar codes by length.
Explains using MATCH parameter to select bar codes based on character strings.
Explains modifying Original Data and adding Additional Data in data editing.
Details the use of comma, quotation marks, asterisk, and hash sign as special characters.
Lists Code Types for editing and the general format for Data Editing formulas.
Explains special characters used as delimiters and specifiers within data editing formulas.
Lists bar codes for Function Keys (F1-F12) and Navigation Keys (Esc, Enter, etc.).
Maps ASCII control characters (NUL, SOH, etc.) to their corresponding bar codes.
Maps special ASCII characters (!, ", #, etc.) to their corresponding bar codes.
Maps ASCII numeric characters (0-9) and symbols to their bar codes.
Maps ASCII uppercase alphabetic characters (A-Z) to their bar codes.
Maps ASCII lowercase alphabetic characters (a-z) to their bar codes.
Maps extended ASCII characters ({, }, ~) and the Delete function to their bar codes.
Details performance (light source, resolution) and decoder (symbologies, interfaces) specifications.
Outlines mechanical, electrical (dimensions, voltage), and environmental (temperature, humidity) specifications.
Lists pin assignments for Keyboard, RS232, TTL (Wand), and USB interfaces.
Suggests trying other bar codes and checking clarity to diagnose scanning issues.
Provides steps to reset the scanner to factory default using SCM.
Recommends testing the scanner on other ports or systems to verify functionality.
Offers solutions for the scanner not emitting light, checking interface and power supply.
Provides steps for a scanner that lights up but does not beep, checking symbology and bar code quality.
Offers solutions for no data output, checking software, ports, and RS232 settings.
Explains issues with Scanner Configuration Manager upload/download and provides workarounds like printing bar codes.
Details the Unitech limited hardware warranty, coverage, and return procedures.
Displays test patterns for basic bar code symbologies like Codabar, Code 39, Code 128, and Code 93.
Displays test patterns for advanced bar code symbologies like EAN-13, UPC-A, MSI Code, and Interleaved 2 of 5.