EasyManua.ls Logo

Unitech MSR120 - (2 Bh) no Data; (2 Ah) Error; (3 Fh) Communication Error; (21 H) Invalid Command

Unitech MSR120
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MSR120 Programmer’s Manual UDN PM010, Rev. 1.1
Section 4 – Commands and Responses 2003/1/21
Last command has been completed without an error condition, and ready for the next command.
+ (2Bh) " No Data
Comments
If host gets the response from reader, it may mean one of following:
1 In case of a "standard format" read command, this response "+" means "no start sentinel (SS) found".
2 In case of a "read error" command, this response "+" means "no history of a previous read error".
* (2Ah) " Error
Comments
If host gets the response from reader, it may mean one of following:
1 No end sentinel (ES).
2 Parity error.
3 LRC error.
? (3Fh) " Communication Error
Comments
If host gets the response from reader, it may mean one of following:
1 Bad parity.
2 Wrong BCC.
3 Receive character time-out (approximately 2mSec).
4 Message more than maximum character allowed.
! (21h) " Invalid Command
Comments
Command issued by the host was not recognized or won’t accept.
: (3Ah) " Power On Report
Comments
The interface has completed its initialization cycle.
~ (7Eh) " Cannot Execute
Comments
Read or encode command cannot be executed due to lack of hardware in the device.
Page 4-5
Proprietary and Confidential Total 36 pages