What causes over shock in UNITY LAUNDRY SYSTEMS UTS40 Laundry Appliance?
- DDr. Louis FigueroaSep 4, 2025
If your UNITY LAUNDRY SYSTEMS Laundry Appliance is experiencing over shock, check if the load in the machine is too small or too large.

What causes over shock in UNITY LAUNDRY SYSTEMS UTS40 Laundry Appliance?
If your UNITY LAUNDRY SYSTEMS Laundry Appliance is experiencing over shock, check if the load in the machine is too small or too large.
How to clear lubrication time on UNITY LAUNDRY SYSTEMS UTS40 Laundry Appliance?
The run times on the UNITY LAUNDRY SYSTEMS Laundry Appliance can be viewed and cleared by pressing the [START] button for 3 seconds from the startup screen.
How to troubleshoot Bkbd comm overtime on UNITY LAUNDRY SYSTEMS Laundry Appliance?
If your UNITY LAUNDRY SYSTEMS Laundry Appliance displays a Bkbd comm overtime error, check the wiring between the HMI and I/0 Board.
How to fix high temp of invt error on UNITY LAUNDRY SYSTEMS UTS40?
If the UNITY LAUNDRY SYSTEMS Laundry Appliance shows a high temperature of invt, clean the lint inside the machine and check the inverter fan.
How to resolve Invt comm overtime on UNITY LAUNDRY SYSTEMS Laundry Appliance?
If your UNITY LAUNDRY SYSTEMS Laundry Appliance is showing an Invt comm overtime error, check the power inverter and the inverter's parameters.
What to do if UNITY LAUNDRY SYSTEMS UTS40 displays an inverter error?
If your UNITY LAUNDRY SYSTEMS Laundry Appliance shows an inverter error, check the inverter itself and its input power.
How to troubleshoot overtime of heat error in UNITY LAUNDRY SYSTEMS UTS40?
If your UNITY LAUNDRY SYSTEMS Laundry Appliance displays an overtime of heat error, examine the heating device and check the temperature sensor.
What causes overtime of fill in UNITY LAUNDRY SYSTEMS UTS40 Laundry Appliance?
If your UNITY LAUNDRY SYSTEMS Laundry Appliance is showing an overtime of fill error, inspect the inlet water filters, ensure the drain valve is closed, and check the level sensor.
What to do if UNITY LAUNDRY SYSTEMS UTS40 shows overtime of drain?
If your UNITY LAUNDRY SYSTEMS Laundry Appliance is experiencing an overtime of drain, verify that the drain valve is opening correctly and check for any blockages in the drain line.
What to do if the UNITY LAUNDRY SYSTEMS UTS40 shows an Emergency Stop error?
If your UNITY LAUNDRY SYSTEMS Laundry Appliance shows an Emergency Stop error, ensure that the emergency stop is released.
| Brand | UNITY LAUNDRY SYSTEMS |
|---|---|
| Model | UTS40 |
| Category | Laundry Appliance |
| Language | English |
Explains DANGER, WARNING, CAUTION, IMPORTANT, NOTE statements for user safety.
Lists critical precautions for safe operation and installation of the machine.
Identifies and explains the various safety decals found on the machine.
Provides guidelines for safe operation, pre-operation checks, and conditions to avoid.
Details responsibilities for installing and using emergency stop devices.
Procedure for inspecting the machine upon delivery for shipping damage.
Identifies the location of the serial plate for warranty and service purposes.
Lists all accessories provided with the washing machine.
Provides contact information for technical assistance and replacement parts.
Technical specifications for the UTS40 model, including motor, capacity, and dimensions.
Detailed diagrams showing the physical dimensions of the UTS40 model.
Technical specifications for the UTS62 model, including motor, capacity, and dimensions.
Detailed diagrams showing the physical dimensions of the UTS62 model.
Specifies minimum clearances for proper operation and maintenance access.
Guidelines for placing the machine on a level, strong, and stable floor.
Procedure and requirements for connecting the water supply to the machine.
Instructions for setting up drain systems, including trough and direct methods.
Safety warnings and procedures for connecting electrical power.
Details on electrical connection types and grounding requirements.
Information on connecting chemical and liquid supplies.
Instructions for safely removing shipping brackets before operation.
Explanation of the controller for self-service vended market operation.
Explanation of the controller for on-premise market operation.
Describes the initial display shown when the machine is powered on.
Displays the interface when the machine is not in use.
Details on starting and monitoring the automatic wash cycle.
How to access and view the machine's cycle count and statistics.
Procedure for viewing and clearing recorded cycle data.
Instructions for changing the user password to access setup menus.
Guide to setting prices for different wash programs.
Detailed steps for setting standard or specific prices.
Steps to enter the programming mode to edit wash cycles.
How to select, add, or delete steps within a wash program.
Instructions for saving modified wash programs.
Lists common alarm codes and their troubleshooting steps.
Describes specific alarms related to the Variable Frequency Drive.
How to access and view the log of recent alarms.
How to find and use the USB port for data transfer.
Uploading machine parameters from a USB drive.
Uploading wash programs from a USB drive.
Downloading machine parameters to a USB drive.
Downloading wash programs to a USB drive.
Procedure for updating the main relay PCB software via USB.
Uploading VFD parameters from USB.
Downloading VFD parameters to USB.
Common issues and solutions during USB operations.
Defines the acceptable coin size range for the mechanism.
Provides diagrams with measurements of the coin mechanism.
Explains the function of switches, buttons, and connectors.
Details on setting teaching mode, price, coin value, and tolerance.
Step-by-step guide to configure coin acceptance for a specific value.
Instructions for modifying the price for wash programs.
Steps to adjust the accepted coin value for channels.
How to adjust coin acceptance tolerance for accuracy.
Procedure to remove pre-configured settings from channels.
Explains the relationship between coin settings and pulse output.
Common problems with the coin mechanism and their solutions.
Recommended cleaning frequency and procedures for the coin acceptor.
Daily checks and cleaning tasks to ensure proper operation.
Weekly checks for leaks, lint, and connections.
Monthly checks for belt tightness and alignment.
Quarterly checks for hinges, bolts, bearings, and shock absorbers.
Explanation of the system that prevents operation during imbalance.
Information on VFD parameters and error viewing.
Causes and solutions when the machine fails to start.
Troubleshooting steps for slow drum rotation.
Reasons for too much water and how to resolve them.
Solutions for vibration issues during the extraction phase.
Causes and fixes for leaks from the machine door.
Troubleshooting steps for excessive water levels in the drum.
Diagnosing issues when the machine does not fill with water.
Identifying and fixing water leaks from hoses or connections.
Troubleshooting steps when the desired water temperature is not reached.
Reasons why the chemical dispenser may not be flushing correctly.