EasyManuals Logo

Universal Robots UR16e Hardware Manual

Universal Robots UR16e
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
The mains supply is equipped with the following:
Connection to ground
Main fuse
Residual current device
It is recommended to install a main switch to power off all equipment in the robot application as an
easy means for lockout-tagout under service. The electrical specifications are shown in the table
below.
Parameter Min Typ Max Unit
Input voltage 100 - 240 VAC
External mains fuse (@ 100-200V) 8 - 16 A
External mains fuse (@ 200-265V) 8 - 16 A
Input frequency 47 - 440 Hz
Stand-by power - - <1.5 W
Nominal operating power 90 150 325 W
Hardware Manual 43 UR5e
4.Electrical Interface
Copyright © 2009–2022 by UniversalRobotsA/S. All rights reserved.

Other manuals for Universal Robots UR16e

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots UR16e and is the answer not in the manual?

Universal Robots UR16e Specifications

General IconGeneral
BrandUniversal Robots
ModelUR16e
CategoryRobotics
LanguageEnglish

Related product manuals