2.12 DIRECT ACCESS FUNCTION KEYS
Three pre-programmed keys are provided on the keypads for directly activating the fire, emergency and silent panic
indications.
Their position and shape are keypad-specific but the icons are the same:
= fire = emergency = silent panic
2.12.1 1067/022 keypad
Hold
(fire), (emergency) or (silent panic): pressed for at least three seconds: the control panel will generate
the respective event without needing to enter any code. Each key must be enabled.
The environmental listening function can be activated automatically at the end of the emergency call on keypads, if they
are duly programmed to do so.
2.12.2 1067/026 keypad
Hold T1 (silent panic), T2 (emergency) or T3 (fire): pressed for at least three seconds: the control panel will generate the
respective event without needing to enter any code. Each key must be enabled.
2.12.3 1058/035 remote control programming key
During programming, the “+” key on the remote control may be configured to activate or deactivate a specific output to
access one of the following technological functions (fire, emergency, panic, silent panic) directly. Hold the “+” key pressed
for at least five seconds to generate the respective alarm event.
2.13 HOW TO STOP ALARMS IN PROGRESS
The procedure for stopping an alarm is shown in detail in paragraph 4.2 Description of alarms and indications.
It is important to remember that:
Entering a valid code on a keypad will stop most alarms.
The vocal alarm call cycle can be stopped by dialling “12” on the telephone which received the call after hearing the
message and the beep (a DTMF tone keypad is needed for this).
For emergency vocal calls, "12" can be dialled after having closed the environmental listening session at the end of
the emergency vocal message repetition.
The vocal alarm call cycle can also be stopped by entering a valid code on the system keypad within the first 30
seconds if the call delay function is enabled.
IMPORTANT! The system will not be EN50131 compliant if vocal only alarm calls are enabled.
IMPORTANT! Alarms calls made using numeric protocol and on ATS4 cannot be stopped.
IMPORTANT! The system will not be EN50131 compliant if alarm calling delay is enabled.
Vocal calls and text messages following burglar events may be interrupted also by disarming the zones assigned to the
telephone numbers programmed for the event. This function may be useful in case of false alarms, for instance.
It is important to note that a call to the first available telephone number cannot be stopped once it has started and will
continue until the end of the attempts. No other calls will be made to the next numbers.

Table of Contents

Other manuals for urmet domus 1067

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the urmet domus 1067 and is the answer not in the manual?

urmet domus 1067 Specifications

General IconGeneral
Brandurmet domus
Model1067
CategoryAntenna
LanguageEnglish

Related product manuals