What to do if UWE SEK-30K Scales display shows a symbol?
- TTara GreenAug 8, 2025
If the UWE Scales displays a symbol, it indicates a low battery warning. Recharge the battery to resolve this issue.
What to do if UWE SEK-30K Scales display shows a symbol?
If the UWE Scales displays a symbol, it indicates a low battery warning. Recharge the battery to resolve this issue.
Why is the weight not accurate on my UWE SEK-30K Scales?
If your UWE Scales weight is not accurate, first check for any objects stuck on the scale and remove them. Also, external factors like wind or RF interference can cause this. Try using the scale in an environment free of such interference.
How to fix UWE Scales that cannot be turned on?
If your UWE Scales cannot be turned on, there might be several reasons: * The adaptor might not be plugged in correctly; re-plug it into the scale. * The rechargeable battery may be low; recharge it. * The adaptor voltage may be incompatible with the electrical outlet; replace the adaptor with one that has the correct voltage.
Why do UWE Scales turn off automatically?
The Auto Power Off function might be enabled on your UWE Scales. To change this setting, enter function F4.
What to do if UWE Scales display shows a low battery symbol?
If your UWE Scales display shows a low battery symbol, it means the battery is low. To resolve this, recharge the battery.
Input numbers for settings, such as HI-OK-LO values.
Set display to zero or input '0'; hold to set OK value for HI-OK-LO.
Input item count for sampling and store sample weight.
Tare off the weight of the load on the platter; full tare is available.
Turn scale on/off, set to zero, and control backlight.
Change weighing units, resolution, and HI-OK-LO range.
Accumulate weight or pieces displayed into memory.
Recall the accumulated total weight or total pieces.
Set the LO limit for HI-OK-LO function.
Set the HI limit for HI-OK-LO function.
Clear previous settings for HI-OK-LO (high, low, standard, range).
Turn the scale off.
Indicates battery charging status (red for charging, green for full).
Lights up when the weight or pieces are lower than the set LO value.
Lights up when the weight or pieces are within the OK value range.
Lights up when the weight or pieces are higher than the set HI value.
An arrow indicating a zero weight status.
An arrow indicating TARE function is active and net weight is shown.
Indicates the battery is low; charge immediately.
An arrow indicating the accumulation function is in use.
An arrow indicating accumulation data is currently shown.
Shows the current weighing unit being employed.
Set the range for Auto Zero Tracking.
Display the span value.
Display software version and perform a full display test.
Display default units and enable/disable units shown in MODE.
Enable or disable the Auto Power Off feature.
Configure Baud Rate and Parity Settings for RS-232.
Enable or disable digital filter for stability.
Select transmission mode for RS-232 (Auto, P-Out, Conti).
Select tare function mode (stable or unstable weight).
Configure sound alarm for HI, OK, LO, or HI/LO values.
Choose relay output mode (Act L or Act H).
| Capacity | 30 kg |
|---|---|
| Auto Power Off | Yes |
| Overload Protection | Yes |
| Units | kg, lb |
| Power | Battery (2 x AA) or AC adapter |