- 57 -
PARAMETER VALUE SUBMENU DESCRIPTION DEFAULT CHAPTER MEMO
SP.AP
Pedestrian Start during the partial opening
phase
PAUS
16
PAUS
Thegatestopsandgoestopause
CHIU
Thegateimmediatelystartsclosing
NO
Thegategoesonwiththeopeningphase
(commandisignored)
CH.AU 0.5”-20’
Pause time for automatic closing
NO
18
NO
Functiondisabled
CH.TR 0.5”-20’
Pause time after transit
NO
11
NO
Functiondisabled
PA.TR
Pause after transit
NO
11
NO
Functiondisabled
SI
Functionenabled
LUCI
Courtesy light
T.LUC
20
T.LUC 0.0”-20’
Timeraftercommand
1.0’
NO
Functiondisabled
CICL 0.0”-20’
Moving+timer
AUX
AUX radio channel function
TIM
20
TIM 0.0”-20’
Timerlight
1.0’
BIST
Bistablelight
MONO
Monostablelight
PRES
Forceddeadmanmode
17
TOUT 0.0”-20’
Bistable+timeout
SPIA
24V output setup
W.L.
14
W.L.
Warninglight
FLASH
Blinker
NO
Nofunction
LP.PA
Blinker during pause time
NO
13
NO
Duringthepausetheblinkerisoff
SI
Duringthepause,theblinkerison

Table of Contents